<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas Steam Boiler - Brit Industrial Boilers</title>
	<atom:link href="https://britboiler.com/product-category/gas-steam-boiler/feed/" rel="self" type="application/rss+xml" />
	<link>https://britboiler.com/product-category/gas-steam-boiler/</link>
	<description>Gas &#38; Biomass Steam Boilers</description>
	<lastBuildDate>Tue, 09 Dec 2025 02:53:29 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://britboiler.com/wp-content/uploads/2025/11/cropped-Brit-Thermal-Energy-Site-Logo-1-32x32.png</url>
	<title>Gas Steam Boiler - Brit Industrial Boilers</title>
	<link>https://britboiler.com/product-category/gas-steam-boiler/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>WNS Three-Pass Fire-Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 08:56:16 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=929</guid>

					<description><![CDATA[<p>1. Full-waveform furnace structure avoids cracking caused by stress concentration, thereby extending boiler's service life.<br />
2. Unique "welding &#38; expansion" process prevents subcooled boiling at the tube and plate welds, thus ensuring a safe, reliable and stable boiler operation.<br />
3. Fire-tube adopts special threaded tube to reduce smoke flow resistance and enhance the heat transfer effect.<br />
4. Frameless outer-clad structure &#38; entire coating with heat-resistant paint minimize the heat losses.<br />
5. Large combustion chamber design enables fuel to burn more fully and thoroughly at a relatively low furnace volume heat load, nitrogen oxides are less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/">WNS Three-Pass Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Three-Pass Fire-Tube Gas Steam Boiler<br />
Product Model: WNS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, meanwhile, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 1t/h≤D≤20t/h; P≤1.25Mpa</p>
<h2><strong>1t/h ~ 5t/h Three-Pass Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>WNS1-1.25-Q</th>
<th>WNS2-1.25-Q</th>
<th>WNS3-1.25-Q</th>
<th>WNS4-1.25-Q</th>
<th>WNS5-1.25-Q</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>1</td>
<td>2</td>
<td>3</td>
<td>4</td>
<td>5</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>3.6</td>
<td>5.0</td>
<td>7.5</td>
<td>11.0</td>
<td>12</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>5.5</td>
<td>6</td>
<td>11</td>
<td>12.5</td>
<td>15</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>3700×1800×2100</td>
<td>4400×2000×2300</td>
<td>4700×2300×2900</td>
<td>5200×2450×2850</td>
<td>5450×2550×2950</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN50</td>
<td>DN65</td>
<td>DN80</td>
<td>DN100</td>
<td>DN100</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN50</td>
<td>2×DN65</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN25</td>
<td>DN32</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>6t/h ~ 20t/h Three-Pass Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model Parameters</th>
<th>WNS6-1.25-Q</th>
<th>WNS8-1.25-Q</th>
<th>WNS10-1.25-Q</th>
<th>WNS15-1.25-Q</th>
<th>WNS20-1.25-Q</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>6</td>
<td>8</td>
<td>10</td>
<td>15</td>
<td>20</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>13.85</td>
<td>20</td>
<td>26</td>
<td>28.2</td>
<td>37.3</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>20/18</td>
<td>24</td>
<td>27</td>
<td>40</td>
<td>52.5</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>5900×2700×3200</td>
<td>6500×2950×3450</td>
<td>7100×3200×3600</td>
<td>7700×4600×5000</td>
<td>8850×3700×4055</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>7900×3800×4650</td>
<td>8534×3800×4650</td>
<td>8650×4650×5000</td>
<td>9200×4660×5100</td>
<td>9900×4850×5600</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN125</td>
<td>DN150</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN65</td>
<td>2×DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN100</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
<td>DN80</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/">WNS Three-Pass Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 07:06:34 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=922</guid>

					<description><![CDATA[<p>1. Water circulation utilizes a combination of forced and natural circulation；Boiler's internal devices are rationally arranged to ensure the medium flowing in the tubes of a single loop will not cause steam and water to boil, with water velocity reasonable, safe and reliable.<br />
2. Flue gas is controlled at around 10m/s, Adjacent tubes in convection tube bundles are connected with stainless steel flat bars to increase tube rigidity and prevent vibration during flue gas scouring. Guide plates are installed at flue bends to eliminate vibration during boiler operation.<br />
3. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
4. Boiler is surrounded by membrane type water-cooled walls on all sides, providing excellent sealing and preventing flue gas leakage, reducing heat loss and improving boiler efficiency.<br />
5. With multiple layers of lightweight insulation cotton overlapped staggeredly, entire coating with heat-resistant paint, it makes heat dissipation loss≤0.15%. Membrane walls around the boiler form a large D-shaped furnace, and furnace volume heat load is ≤500kw, which is more conducive to low-nitrogen emissions with nitrogen oxides less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/">SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Low Nitrogen Condensing Water Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> SZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, meanwhile, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> D≤40t/h; P≤2.5MPa; T≤450℃</p>
<h2><strong>2t/h &#8211; 10t/h Low Nitrogen Condensing Water Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>SZS2</th>
<th>SZS3</th>
<th>SZS4</th>
<th>SZS6</th>
<th>SZS10</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>2</td>
<td>3</td>
<td>4</td>
<td>6</td>
<td>10</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>2.5</td>
<td>2.5</td>
<td>2.5</td>
<td>2.5</td>
<td>1.25/1.6/2.5</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>226</td>
<td>226</td>
<td>226</td>
<td>226</td>
<td>194/204/226</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td>/</td>
<td>/</td>
<td>/</td>
<td>/</td>
<td>/</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>3.9</td>
<td>4.6</td>
<td>6.9</td>
<td>7.6</td>
<td>10.2</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>9.5</td>
<td>11</td>
<td>13</td>
<td>19</td>
<td>30</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>4200×2600×3300</td>
<td>4800×2900×3300</td>
<td>5300×2900×3000</td>
<td>6200×2900×3700</td>
<td>6900×3300×3700</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>4750×4000×3300</td>
<td>5400×4300×3300</td>
<td>5900×4990×4025</td>
<td>6800×4990×4500</td>
<td>9075×5295×4500</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
<td>DN125</td>
<td>DN150</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN65</td>
<td>2×DN80</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN50</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, We can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>15t/h &#8211; 40t/h Low Nitrogen Condensing Water Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model<br />
Parameters</th>
<th>SZS15</th>
<th>SZS20</th>
<th>SZS25</th>
<th>SZS30</th>
<th>SZS35</th>
<th>SZS40</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>15</td>
<td>20</td>
<td>25</td>
<td>30</td>
<td>35</td>
<td>40</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="6">≤450</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>13</td>
<td>14.2</td>
<td>16.4</td>
<td>20</td>
<td>25</td>
<td>27</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="6">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>34</td>
<td>46</td>
<td>50</td>
<td>60</td>
<td>65</td>
<td>85</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>7900×3660×3850</td>
<td>8900×4000×3900</td>
<td>10050×4200×4100</td>
<td>11700×4200×4200</td>
<td>12000×4200×4200</td>
<td>13500×4500×4200</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>9320×6400×4725</td>
<td>11000×6200×4760</td>
<td>1360×6855×4590</td>
<td>3570×6365×5015</td>
<td>5480×6845×6070</td>
<td>15500×8400×6200</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
<td>DN250</td>
</tr>
<tr>
<td>Safety valve</td>
<td>DN80, DN100</td>
<td>2×DN100</td>
<td>DN100+DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN100</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, We can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/">SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DHS Vertical (Modular) Corner Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 08:19:19 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=902</guid>

					<description><![CDATA[<p>1. Boiler proper utilizes self-supporting vertical corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.<br />
2. Steam boiler has a single drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.<br />
3. Steam boiler utilizes natural circulation + forced circulation (auxiliary). Vertical layout offers a greater height difference than traditional products, ensuring safer water circulation.<br />
4. Large second-passage space provides ample heating surface arrangement in boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high efficiency.<br />
5. Equal flue gas velocity design for dense convection heating surfaces makes flue gas velocity rationally controlled, prevents shaking of the heating surface.<br />
6. Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.<br />
7. Modular design, high assembly degree, short installation period, small base space, more suitable for large capacity boilers.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/">DHS Vertical (Modular) Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical (Modular) Corner Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> DHS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 60t/h&lt;D≤160t/h; P≤9.8MPa; T≤540 ℃</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>DHS40 (Modular)</th>
<th>DHS50 (Modular)</th>
<th>DHS65 (Modular)</th>
<th>DHS75 (Modular)</th>
<th>DHS100 (Modular)</th>
<th>DHS130 (Modular)</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>40</td>
<td>50</td>
<td>65</td>
<td>75</td>
<td>100</td>
<td>130</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td colspan="6">1.25～9.8</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td colspan="6">194(1.25MPa) / 204(1.6MPa) / 226(2.5MPa) / 250(3.82MPa)</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="6">≤540</td>
</tr>
<tr>
<td>Rated feed water temperature (℃)</td>
<td colspan="6">104(P≤3.82MPa) / 128(P≤5.4MPa) / 157(P≤9.8MPa)</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>22.3</td>
<td>27.5</td>
<td>28.6</td>
<td>33.3</td>
<td>40.2</td>
<td>46.7</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99.2</td>
<td>≥99.2</td>
<td>≥99.2</td>
<td>≥99.3</td>
<td>≥99.5</td>
<td>≥99.7</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="6">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>30</td>
<td>37</td>
<td>42</td>
<td>45</td>
<td>53</td>
<td>65</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>8.6×4×12.4</td>
<td>11×4.1×13.2</td>
<td>11.2×4.2×15.9</td>
<td>11.6×4.2×16.5</td>
<td>14×4.3×20.5</td>
<td>10.6×8.3×15.5</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>10.2×5.5×13.2</td>
<td>12.4×7.7×14</td>
<td>12.7×7.8×16.8</td>
<td>13×8×17.3</td>
<td>15.5×9.6×21.3</td>
<td>12.2×10.8×16.3</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface<br />
diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300</td>
<td>DN300</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN250</td>
<td>1×DN250 / 1×DN300</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN100</td>
<td>DN100</td>
<td>DN125</td>
<td>DN125</td>
<td>DN150</td>
<td>DN150</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/">DHS Vertical (Modular) Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DZS Horizontal Package Corner Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 04:03:00 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=894</guid>

					<description><![CDATA[<ol>
<li>Boiler proper utilizes self-supporting horizontal corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.</li>
<li>Steam boiler has a single drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.</li>
<li>Steam boiler utilizes natural circulation + forced circulation (auxiliary). Single drum layout offers a greater height difference than traditional products, ensuring safer water circulation.</li>
<li>Convection heating surface utilizes smooth tube + spiral fin tube structure, providing ample heating surface area in the boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high thermal efficiency.</li>
<li>Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.</li>
<li>Horizontal structure fully assembled before delivery with low shipping cost, less installation workload and short installation period.</li>
</ol>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/">DZS Horizontal Package Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Horizontal Package Corner Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> DZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 1t/h≤D≤60t/h; P≤3.82Mpa; T≤450℃</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Parameters / Model</th>
<th>DZS20</th>
<th>DZS25</th>
<th>DZS30</th>
<th>DZS35</th>
<th>DZS40</th>
<th>DZS50</th>
<th>DZS60</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>20</td>
<td>25</td>
<td>30</td>
<td>35</td>
<td>40</td>
<td>50</td>
<td>60</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td colspan="7">1.25/1.6/2.5/3.82</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td colspan="7">194/204/226/250</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="7">≤450</td>
</tr>
<tr>
<td>Rated feed water temperature (℃)</td>
<td colspan="7">104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>10</td>
<td>12.5</td>
<td>15</td>
<td>17</td>
<td>19</td>
<td>24</td>
<td>27.8</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="7">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>43.2</td>
<td>46.7</td>
<td>60.6</td>
<td>62.6</td>
<td>66.3</td>
<td>84</td>
<td>95</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>9200×3800<br />
×3600</td>
<td>10800×3900<br />
×3700</td>
<td>12000×4200<br />
×4000</td>
<td>12600×4400<br />
×4000</td>
<td>13000×4600<br />
×4200</td>
<td>13500×4800<br />
×4200</td>
<td>13500×5500<br />
×4600</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>11400×6600<br />
×5100</td>
<td>12900×6800<br />
×5200</td>
<td>14500×7500<br />
×5500</td>
<td>15200×8600<br />
×5500</td>
<td>15500×8900<br />
×5700</td>
<td>16000×9900<br />
×5700</td>
<td>16000×10000<br />
×5900</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN100</td>
<td>2×DN125</td>
<td>2×DN125</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN100</td>
<td>DN100</td>
<td>DN125</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/">DZS Horizontal Package Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WNS Condensing Fire-Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-condensing-fire-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 01:33:51 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=884</guid>

					<description><![CDATA[<p>1. Full-waveform furnace structure avoids cracking caused by stress concentration, extending boiler's service life.<br />
2. Unique "welding &#38; expansion" process prevents subcooled boiling at the tube and plate welds, ensuring a safe, reliable and stable boiler operation.<br />
3. Fire-tube adopts special threaded tube to reduce smoke flow resistance and enhance the heat transfer effect.<br />
4. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
5. Frameless outer-clad structure &#38; entire coating with heat-resistant paint minimize the heat losses.<br />
6. Large combustion chamber design enables fuel to burn more fully and thoroughly at a relatively low furnace volume heat load, and nitrogen oxides are less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-condensing-fire-tube-gas-steam-boiler/">WNS Condensing Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Condensing Fire-Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> WNS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 1t/h≤D≤20t/h; P≤1.6Mpa</p>
<h2><strong>1t/h ~ 6t/h Condensing Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th style="border: 1px solid #000; padding: 6px;">Model Parameters</th>
<th style="border: 1px solid #000; padding: 6px;">WNS1-1.25-Q</th>
<th style="border: 1px solid #000; padding: 6px;">WNS2-1.25-Q</th>
<th style="border: 1px solid #000; padding: 6px;">WNS3-1.25-Q</th>
<th style="border: 1px solid #000; padding: 6px;">WNS4-1.25-Q/<br />
WNS4-1.6-Q</th>
<th style="border: 1px solid #000; padding: 6px;">WNS6-1.25-Q/<br />
WNS6-1.6-Q</th>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Rated evaporation (T/H)</td>
<td style="border: 1px solid #000; padding: 6px;">1</td>
<td style="border: 1px solid #000; padding: 6px;">2</td>
<td style="border: 1px solid #000; padding: 6px;">3</td>
<td style="border: 1px solid #000; padding: 6px;">4</td>
<td style="border: 1px solid #000; padding: 6px;">6</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Rated working pressure (MPa)</td>
<td style="border: 1px solid #000; padding: 6px;">1.25</td>
<td style="border: 1px solid #000; padding: 6px;">1.25</td>
<td style="border: 1px solid #000; padding: 6px;">1.25</td>
<td style="border: 1px solid #000; padding: 6px;">1.25 / 1.6</td>
<td style="border: 1px solid #000; padding: 6px;">1.25 / 1.6</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Saturated steam temperature (℃)</td>
<td style="border: 1px solid #000; padding: 6px;">194</td>
<td style="border: 1px solid #000; padding: 6px;">194</td>
<td style="border: 1px solid #000; padding: 6px;">194</td>
<td style="border: 1px solid #000; padding: 6px;">194 / 204</td>
<td style="border: 1px solid #000; padding: 6px;">194 / 204</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Feed water temperature (℃)</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Full water capacity (m³)</td>
<td style="border: 1px solid #000; padding: 6px;">3</td>
<td style="border: 1px solid #000; padding: 6px;">5.3</td>
<td style="border: 1px solid #000; padding: 6px;">7.5</td>
<td style="border: 1px solid #000; padding: 6px;">12</td>
<td style="border: 1px solid #000; padding: 6px;">15</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Design thermal efficiency (%)</td>
<td style="border: 1px solid #000; padding: 6px;">≥99</td>
<td style="border: 1px solid #000; padding: 6px;">≥99</td>
<td style="border: 1px solid #000; padding: 6px;">≥99</td>
<td style="border: 1px solid #000; padding: 6px;">≥99</td>
<td style="border: 1px solid #000; padding: 6px;">≥99</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Exhaust gas temperature (℃)</td>
<td style="border: 1px solid #000; padding: 6px;">≤65</td>
<td style="border: 1px solid #000; padding: 6px;">≤65</td>
<td style="border: 1px solid #000; padding: 6px;">≤65</td>
<td style="border: 1px solid #000; padding: 6px;">≤65</td>
<td style="border: 1px solid #000; padding: 6px;">≤65</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Design fuel</td>
<td style="border: 1px solid #000; padding: 6px;" colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Transport weight of the largest component (t)</td>
<td style="border: 1px solid #000; padding: 6px;">5.5</td>
<td style="border: 1px solid #000; padding: 6px;">7.4</td>
<td style="border: 1px solid #000; padding: 6px;">11</td>
<td style="border: 1px solid #000; padding: 6px;">14</td>
<td style="border: 1px solid #000; padding: 6px;">20</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Dimensions of boiler proper (L×W×H) (mm)</td>
<td style="border: 1px solid #000; padding: 6px;">3700×1800×2100</td>
<td style="border: 1px solid #000; padding: 6px;">4200×2000×2300</td>
<td style="border: 1px solid #000; padding: 6px;">4700×2300×2900</td>
<td style="border: 1px solid #000; padding: 6px;">5300×2450×2900</td>
<td style="border: 1px solid #000; padding: 6px;">5650×2600×3150</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Dimensions after installation (L×W×H) (mm)</td>
<td style="border: 1px solid #000; padding: 6px;">4600×3300×3100</td>
<td style="border: 1px solid #000; padding: 6px;">5200×3260×3500</td>
<td style="border: 1px solid #000; padding: 6px;">5740×3180×3900</td>
<td style="border: 1px solid #000; padding: 6px;">6300×3500×4000</td>
<td style="border: 1px solid #000; padding: 6px;">7000×3700×4500</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface<br />
diameter (mm)</th>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Main steam valve</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
<td style="border: 1px solid #000; padding: 6px;">DN65</td>
<td style="border: 1px solid #000; padding: 6px;">DN80</td>
<td style="border: 1px solid #000; padding: 6px;">DN100</td>
<td style="border: 1px solid #000; padding: 6px;">DN125</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Safety valve</td>
<td style="border: 1px solid #000; padding: 6px;">2×DN40</td>
<td style="border: 1px solid #000; padding: 6px;">2×DN40</td>
<td style="border: 1px solid #000; padding: 6px;">2×DN40</td>
<td style="border: 1px solid #000; padding: 6px;">2×DN50</td>
<td style="border: 1px solid #000; padding: 6px;">2×DN65</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Water inlet valve</td>
<td style="border: 1px solid #000; padding: 6px;">DN25</td>
<td style="border: 1px solid #000; padding: 6px;">DN25</td>
<td style="border: 1px solid #000; padding: 6px;">DN40</td>
<td style="border: 1px solid #000; padding: 6px;">DN40</td>
<td style="border: 1px solid #000; padding: 6px;">DN40</td>
</tr>
<tr>
<td style="border: 1px solid #000; padding: 6px;">Blowdown valve</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
<td style="border: 1px solid #000; padding: 6px;">DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>8t/h ~ 20t/h Condensing Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model Parameters</th>
<th>WNS8-1.25-Q/<br />
WNS8-1.6-Q</th>
<th>WNS10-1.25-Q/<br />
WNS10-1.6-Q</th>
<th>WNS12-1.25-Q/<br />
WNS12-1.6-Q</th>
<th>WNS15-1.25-Q/<br />
WNS15-1.6-Q</th>
<th>WNS20-1.25-Q/<br />
WNS20-1.6-Q</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>8</td>
<td>10</td>
<td>12</td>
<td>15</td>
<td>20</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25/1.6</td>
<td>1.25/1.6</td>
<td>1.25/1.6</td>
<td>1.25/1.6</td>
<td>1.25/1.6</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>194/204</td>
<td>194/204</td>
<td>194/204</td>
<td>194/204</td>
<td>194/204</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>20</td>
<td>26</td>
<td>28.2</td>
<td>28.2</td>
<td>38.6</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td style="text-align: left;" colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>24</td>
<td>28</td>
<td>31</td>
<td>34</td>
<td>43</td>
</tr>
<tr>
<td>Dimensions of Boiler proper (L×W×H) (mm)</td>
<td>6350×2950×3355</td>
<td>6973×2950×3600</td>
<td>7300×3210×3700</td>
<td>7600×3450×3770</td>
<td>8600×3620×4000</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>7900×3800×4650</td>
<td>8534×3800×4650</td>
<td>8650×4650×5000</td>
<td>9200×4660×5100</td>
<td>9900×4850×5600</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface<br />
diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve (mm)</td>
<td>DN150</td>
<td>DN150</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
</tr>
<tr>
<td>Safety valve (mm)</td>
<td>2×DN80</td>
<td>2×DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN100</td>
</tr>
<tr>
<td>Water inlet valve (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
<td>DN65</td>
</tr>
<tr>
<td>Blowdown valve (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-condensing-fire-tube-gas-steam-boiler/">WNS Condensing Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DHS(DC) Skid-Mounted Condensing Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhsdc-skid-mounted-condensing-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Sat, 22 Nov 2025 07:24:02 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=858</guid>

					<description><![CDATA[<p>1. Integrated FIR low-nitrogen burner technology, corner tube technology and plate and shell deep condensation technology.<br />
2. Unique "ultra-low nitrogen internal circulation technology", with gas consumption per ton of steam ≤ 74.5 Nm³.<br />
3.Deep condensation, with flue gas temperature ≤ 48°C (in the condition of no condensate water recovery);<br />
4. Multi-unit group control to avoid "large horse pulling small cart"<br />
5. Small in Size, flexible to be mounted.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhsdc-skid-mounted-condensing-gas-steam-boiler/">DHS(DC) Skid-Mounted Condensing Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Skid-Mounted Condensing Gas Steam Boiler<br />
<strong>Product Model:</strong> DHS(DC) Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Main body in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 4t/h≤D≤6t/h; P≤3.82Mpa</p>
<h2><strong>Feature &#8211; More Energy Saving</strong></h2>
<p>1. Deep condensation, smoke temperature ≤ 48℃. By comprehensively applying various enhanced heat exchange technologies and making full use of flue gas condensation heat, thermal efficiency of boiler is up to 103%, which can save 4-6 m3 natural gas per ton of steam than common condensing boiler, more energy saving.<br />
2. Large boiler drum space &amp; unique design of steam drum internals provides better steam-water separation effect with steam dryness achieving ≥ 99%. Low pipe losses with high energy efficiency.<br />
3. Fast steam generation (Steam can be generated in 5 minutes from cold state). Multiple boilers can be connected in parallel with a wide load adjustment range and more energy saving operation.</p>
<h2><strong>4t/h ~ 6t/h Skid-Mounted Condensing Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th style="padding: 10px; text-align: left; width: 60%;">Model Parameters</th>
<th style="padding: 10px; width: 20%;">DHS4</th>
<th style="padding: 10px; width: 20%;">DHS6</th>
</tr>
<tr>
<td style="padding: 10px;">Rated evaporation (T/H)</td>
<td style="padding: 10px; text-align: center;">4</td>
<td style="padding: 10px; text-align: center;">6</td>
</tr>
<tr>
<td style="padding: 10px;">Rated working pressure (MPa)</td>
<td style="padding: 10px; text-align: center;" colspan="2">1.25/1.6/2.5</td>
</tr>
<tr>
<td style="padding: 10px;">Saturated steam temperature (°C)</td>
<td style="padding: 10px; text-align: center;" colspan="2">194/204/226</td>
</tr>
<tr>
<td style="padding: 10px;">Rated feed water temperature (°C)</td>
<td style="padding: 10px; text-align: center;">20</td>
<td style="padding: 10px; text-align: center;">20</td>
</tr>
<tr>
<td style="padding: 10px;">Full water capacity (m³)</td>
<td style="padding: 10px; text-align: center;">3.3</td>
<td style="padding: 10px; text-align: center;">3.7</td>
</tr>
<tr>
<td style="padding: 10px;">Operating water capacity (m³)</td>
<td style="padding: 10px; text-align: center;">2.3</td>
<td style="padding: 10px; text-align: center;">2.7</td>
</tr>
<tr>
<td style="padding: 10px;">Design thermal efficiency (%)</td>
<td style="padding: 10px; text-align: center;" colspan="2">103</td>
</tr>
<tr>
<td style="padding: 10px;">Exhaust gas temperature (°C)</td>
<td style="padding: 10px; text-align: center;" colspan="2">48</td>
</tr>
<tr>
<td style="padding: 10px;">Design fuel</td>
<td style="padding: 10px; text-align: center;" colspan="2">Natural gas, etc.</td>
</tr>
<tr>
<td style="padding: 10px;">Gas pressure (KPa)</td>
<td style="padding: 10px; text-align: center;">30~40</td>
<td style="padding: 10px; text-align: center;">30~40</td>
</tr>
<tr>
<td style="padding: 10px;">Fuel consumption (Nm³/h)</td>
<td style="padding: 10px; text-align: center;">298</td>
<td style="padding: 10px; text-align: center;">447</td>
</tr>
<tr>
<td style="padding: 10px;">Transport weight of the largest component(t)</td>
<td style="padding: 10px; text-align: center;">21</td>
<td style="padding: 10px; text-align: center;">24</td>
</tr>
<tr>
<td style="padding: 10px;">Operating weight (t)</td>
<td style="padding: 10px; text-align: center;">26</td>
<td style="padding: 10px; text-align: center;">30</td>
</tr>
<tr>
<td style="padding: 10px;">Dimensions after installation (L×W×H) (mm)</td>
<td style="padding: 10px; text-align: center;">5070×3740×5256</td>
<td style="padding: 10px; text-align: center;">5370×3740×5256</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter (mm)</th>
</tr>
<tr>
<td style="padding: 10px; padding-left: 20px;">Main steam valve</td>
<td style="padding: 10px; text-align: center;">DN100</td>
<td style="padding: 10px; text-align: center;">DN125</td>
</tr>
<tr>
<td style="padding: 10px; padding-left: 20px;">Safety valve</td>
<td style="padding: 10px; text-align: center;">2-DN50</td>
<td style="padding: 10px; text-align: center;">2-DN65</td>
</tr>
<tr>
<td style="padding: 10px; padding-left: 20px;">Water inlet valve</td>
<td style="padding: 10px; text-align: center;">DN40</td>
<td style="padding: 10px; text-align: center;">DN40</td>
</tr>
<tr>
<td style="padding: 10px; padding-left: 20px;">Blowdown valve</td>
<td style="padding: 10px; text-align: center;">DN50</td>
<td style="padding: 10px; text-align: center;">DN50</td>
</tr>
<tr>
<td style="padding: 10px; padding-left: 20px;">Stack</td>
<td style="padding: 10px; text-align: center;">φ400</td>
<td style="padding: 10px; text-align: center;">φ500</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhsdc-skid-mounted-condensing-gas-steam-boiler/">DHS(DC) Skid-Mounted Condensing Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>