<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas Hot Water Boiler - Brit Industrial Boilers</title>
	<atom:link href="https://britboiler.com/product-category/gas-hot-water-boiler/feed/" rel="self" type="application/rss+xml" />
	<link>https://britboiler.com/product-category/gas-hot-water-boiler/</link>
	<description>Gas &#38; Biomass Steam Boilers</description>
	<lastBuildDate>Tue, 09 Dec 2025 02:48:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://britboiler.com/wp-content/uploads/2025/11/cropped-Brit-Thermal-Energy-Site-Logo-1-32x32.png</url>
	<title>Gas Hot Water Boiler - Brit Industrial Boilers</title>
	<link>https://britboiler.com/product-category/gas-hot-water-boiler/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SZS Low Nitrogen Water Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 07:33:37 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=925</guid>

					<description><![CDATA[<p>1. Water circulation utilizes a combination of forced and natural circulation；Boiler's internal devices are rationally arranged to ensure the medium flowing in the tubes of a single loop will not cause steam and water to boil, with water velocity reasonable, safe and reliable.<br />
2. Flue gas is controlled at around 10m/s, Adjacent tubes in convection tube bundles are connected with stainless steel flat bars to increase tube rigidity and prevent vibration during flue gas scouring. Guide plates are installed at flue bends to eliminate vibration during boiler operation.<br />
3. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
4. Boiler is surrounded by membrane type water-cooled walls on all sides, providing excellent sealing and preventing flue gas leakage, reducing heat loss and improving boiler efficiency.<br />
5. With multiple layers of lightweight insulation cotton overlapped staggeredly, entire coating with heat-resistant paint, it makes heat dissipation loss≤0.15%. Membrane walls around the boiler form a large D-shaped furnace, and furnace volume heat load is ≤500kw,  which is more conducive to low-nitrogen emissions with nitrogen oxides less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/">SZS Low Nitrogen Water Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Low Nitrogen Water Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> SZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 14MW≤Q≤29MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model /<br />
Parameters</th>
<th>SZS14-1.25/115/70-Q</th>
<th>SZS17.5-1.25/115/70-Q</th>
<th>SZS21-1.25/115/70-Q</th>
<th>SZS29-1.6/130/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>14</td>
<td>17.5</td>
<td>21</td>
<td>29</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>115</td>
<td>115</td>
<td>115</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>12.7</td>
<td>16.4</td>
<td>19.1</td>
<td>23.6</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="4">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>45</td>
<td>50</td>
<td>62</td>
<td>70</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>9820×3780×3850</td>
<td>9820×4070×4000</td>
<td>10700×4200×4000</td>
<td>13400×4200×4200</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>11240×6465×5085</td>
<td>11240×6765×5235</td>
<td>12120×7000×5330</td>
<td>14840×7215×5535</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300(2×DN200+DN150)</td>
</tr>
<tr>
<td>Backwater valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>DN150+DN50</td>
<td>DN150+DN100</td>
<td>20×DN150</td>
<td>20×DN150</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/">SZS Low Nitrogen Water Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 08:58:51 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=905</guid>

					<description><![CDATA[<p>1. Boiler proper utilizes self-supporting vertical corner tube structure, with high strength &#38;amp; stability, safe and reliable without shaking or surging.<br />
2. Hot water boiler has no drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.<br />
3. Hot water boiler utilizes forced circulation + natural circulation (auxiliary). Vertical layout offers a greater height difference than traditional products, ensuring safer water circulation.<br />
4. Large second-passage space provides ample heating surface arrangement in boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high efficiency.<br />
5. Equal flue gas velocity design for dense convection heating surfaces makes flue gas velocity rationally controlled, prevents shaking of the heating surface.<br />
6. Reserving sufficient space between densely heated surfaces for inspection &#38;amp; maintenance makes easy entry &#38;amp; exit of furnace &#38;amp; furnace chamber, making inspection &#38;amp; maintenance more convenient.<br />
7. Modular design, high assembly degree, short installation period, small base space, more suitable for large capacity boilers.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/">QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical (Modular) Corner Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> QXS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 29MW≤Q≤116MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>QXS29-1.6/130/70-Q (Modular)</th>
<th>QXS46-1.6/130/70-Q (Modular)</th>
<th>QXS58-1.6/130/70-Q (Modular)</th>
<th>QXS70-1.6/130/70-Q (Modular)</th>
<th>QXS116-1.6/130/70-Q (Modular)</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>29</td>
<td>46</td>
<td>58</td>
<td>70</td>
<td>116</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>25.6</td>
<td>38.7</td>
<td>41.5</td>
<td>49.7</td>
<td>61.4</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96.3</td>
<td>≥96.5</td>
<td>≥96.8</td>
<td>≥96.8</td>
<td>≥97.1</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>29.5</td>
<td>41.6</td>
<td>44.2</td>
<td>52.8</td>
<td>31.6</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>8.2×4×11.2</td>
<td>9.4×4.2×11.6</td>
<td>11.2×4.2×13.5</td>
<td>11.8×4.2×14.2</td>
<td>12.2×8.4×13.5</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>9.6×6.1×11.2</td>
<td>10.8×6.4×12.6</td>
<td>13.2×6.4×15.5</td>
<td>14.3×6.4×16.8</td>
<td>15×10.9×15.5</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN300</td>
<td>DN400</td>
<td>2×DN400</td>
</tr>
<tr>
<td>Backwater valve</td>
<td>DN300</td>
<td>DN300</td>
<td>DN350</td>
<td>DN400</td>
<td>DN500</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
<td>2×DN200</td>
<td>2×DN250</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/">QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>QXS Horizontal Package Corner Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 07:44:26 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=897</guid>

					<description><![CDATA[<ol>
<li>Boiler proper utilizes self-supporting horizontal corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.</li>
<li>Hot water boiler has no drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.</li>
<li>Hot water boiler utilizes forced circulation + natural circulation (auxiliary. Single drum layout offers a greater height difference than traditional products, ensuring safer water circulation.</li>
<li>Convection heating surface utilizes smooth tube + spiral fin tube structure, providing ample heating surface area in the boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high thermal efficiency.</li>
<li>Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.</li>
<li>Horizontal structure fully assembled before delivery with low shipping cost, less installation workload and short installation period.</li>
</ol>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/">QXS Horizontal Package Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> QXS Horizontal Package Corner Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> QXS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 14MW≤Q≤58MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>QXS14-1.25/115/70-Q</th>
<th>QXS17.5-1.25/115/70-Q</th>
<th>QXS21-1.25/115/70-Q</th>
<th>QXS29-1.6/130/70-Q</th>
<th>QXS35-1.6/130/70-Q</th>
<th>QXS46-1.6/130/70-Q</th>
<th>QXS58-1.6/130/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>14</td>
<td>17.5</td>
<td>21</td>
<td>29</td>
<td>35</td>
<td>46</td>
<td>58</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>115</td>
<td>115</td>
<td>115</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>16.7</td>
<td>18.9</td>
<td>23.2</td>
<td>25.6</td>
<td>26.1</td>
<td>28.2</td>
<td>31.5</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="7">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>43.6</td>
<td>46.8</td>
<td>59.8</td>
<td>73.2</td>
<td>82.7</td>
<td>91.1</td>
<td>98.9</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>9000×3800<br />
×3300</td>
<td>10400×3900<br />
×3400</td>
<td>11500×4000<br />
×3500</td>
<td>12700×4200<br />
×3800</td>
<td>13500×5000<br />
×4200</td>
<td>15200×5200<br />
×4350</td>
<td>17500×5500<br />
×4600</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>11000×6600<br />
×4900</td>
<td>12500×6800<br />
×5000</td>
<td>14300×6800<br />
×5500</td>
<td>15500×7000<br />
×6000</td>
<td>16500×8200<br />
×6200</td>
<td>18000×8500<br />
×6350</td>
<td>20000×9200<br />
×6600</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>DN250</td>
<td>DN250</td>
<td>2×DN200</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN250</td>
<td>2×DN300</td>
</tr>
<tr>
<td>Return Water Valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300</td>
<td>DN300</td>
<td>DN350</td>
<td>DN400</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN100</td>
<td>DN100+DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/">QXS Horizontal Package Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>WNS Three-Pass Fire-Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/wns-series-three-pass-fire-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 03:09:49 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=889</guid>

					<description><![CDATA[<p>WNS Series Three-Pass Fire-Tube Gas Hot Water Boiler<br />
1. Full-waveform furnace structure avoids cracking caused by stress concentration, extending boiler's service life.<br />
2. Unique "welding &#38; expansion" process prevents subcooled boiling at the tube and plate welds, ensuring a safe, reliable and stable boiler operation.<br />
3. Fire-tube adopts special threaded tube to reduce smoke flow resistance and enhance the heat transfer effect. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
4. Frameless outer-clad structure &#38; entire coating with heat-resistant paint minimize the heat losses.<br />
5. Large combustion chamber design enables fuel to burn more fully and thoroughly at a relatively low furnace volume heat load, and nitrogen oxides are less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/wns-series-three-pass-fire-tube-gas-hot-water-boiler/">WNS Three-Pass Fire-Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Three-Pass Fire-Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> WNS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 0.7MW≤Q≤14MW</p>
<h2><strong>0.7 ~ 3.5MW Three-Pass Fire-Tube Gas Hot Water Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model Parameters</th>
<th>WNS0.7-1.0/95/70-Q</th>
<th>WNS1.4-1.0/95/70-Q</th>
<th>WNS2.1-1.0/95/70-Q</th>
<th>WNS2.8-1.0/95/70-Q</th>
<th>WNS3.5-1.0/95/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>0.7</td>
<td>1.4</td>
<td>2.1</td>
<td>2.8</td>
<td>3.5</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>95</td>
<td>95</td>
<td>95</td>
<td>95</td>
<td>95</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>2</td>
<td>2.8</td>
<td>4.1</td>
<td>5.9</td>
<td>6.1</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥95</td>
<td>≥95</td>
<td>≥95</td>
<td>≥95</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>3.2</td>
<td>4.3</td>
<td>5.3</td>
<td>8.2</td>
<td>9</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>3805×1400×1730</td>
<td>4100×1600×1930</td>
<td>4705×1800×2130</td>
<td>5200×2050×2385</td>
<td>5305×2100×2440</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>5240×1400×2600</td>
<td>6030×1600×2800</td>
<td>6800×1800×3120</td>
<td>7190×2300×3550</td>
<td>7325×2245×3605</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; background: #f5f5f5;" colspan="6">Interface diameter (mm)</th>
</tr>
<tr>
<td>Outlet valve (mm)</td>
<td>DN80</td>
<td>DN100</td>
<td>DN125</td>
<td>DN150</td>
<td>DN200</td>
</tr>
<tr>
<td>Backwater valve (mm)</td>
<td>DN80</td>
<td>DN100</td>
<td>DN125</td>
<td>DN150</td>
<td>DN200</td>
</tr>
<tr>
<td>Safety valve (mm)</td>
<td>DN40</td>
<td>DN50</td>
<td>DN80</td>
<td>2×DN50</td>
<td>DN80, DN50</td>
</tr>
<tr>
<td>Blowdown valve (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>4.2 ~ 14MW Three-Pass Fire-Tube Gas Hot Water Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model Parameters</th>
<th>WNS4.2-1.0/95/70-Q</th>
<th>WNS5.6-1.0/95/70-Q</th>
<th>WNS7-1.0/95/70-Q</th>
<th>WNS10.5-1.25/115/70-Q<br />
WNS10.5-1.25/130/70-Q</th>
<th>WNS14-1.25/115/70-Q<br />
WNS14-1.25/130/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>4.2</td>
<td>5.6</td>
<td>7</td>
<td>10.5</td>
<td>14</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1</td>
<td>1</td>
<td>1</td>
<td>1.25</td>
<td>1.25</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>95</td>
<td>95</td>
<td>95</td>
<td>115/130</td>
<td>115/130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>8</td>
<td>10.9</td>
<td>12.6</td>
<td>18.7</td>
<td>25.1</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component(t)</td>
<td>11.3</td>
<td>13.9</td>
<td>16.5</td>
<td>25.2</td>
<td>34.9</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>5735×2300×2640</td>
<td>6315×2505×2840</td>
<td>7025×2605×2940</td>
<td>7835×2960×3285</td>
<td>8265×3265×3585</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>7750×2505×3830</td>
<td>8420×2705×4010</td>
<td>9145×2755×4010</td>
<td>9995×3110×4450</td>
<td>10900×3415×4760</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface<br />
diameter (mm)</th>
</tr>
<tr>
<td>Outlet valve (mm)</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
</tr>
<tr>
<td>Backwater valve (mm)</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
</tr>
<tr>
<td>Safety valve (mm)</td>
<td>DN80, DN50</td>
<td>2×DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>DN150+DN50 / 2×DN100</td>
</tr>
<tr>
<td>Blowdown valve (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/wns-series-three-pass-fire-tube-gas-hot-water-boiler/">WNS Three-Pass Fire-Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
