<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biomass Steam Boiler - Brit Industrial Boilers</title>
	<atom:link href="https://britboiler.com/product-category/biomass-steam-boiler/feed/" rel="self" type="application/rss+xml" />
	<link>https://britboiler.com/product-category/biomass-steam-boiler/</link>
	<description>Gas &#38; Biomass Steam Boilers</description>
	<lastBuildDate>Tue, 09 Dec 2025 02:44:24 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://britboiler.com/wp-content/uploads/2025/11/cropped-Brit-Thermal-Energy-Site-Logo-1-32x32.png</url>
	<title>Biomass Steam Boiler - Brit Industrial Boilers</title>
	<link>https://britboiler.com/product-category/biomass-steam-boiler/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SZL Double-drum Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 05:50:59 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=918</guid>

					<description><![CDATA[<p>1. Boiler proper adopts full membrane wall structure and light insulation material, with less air leakage &#38; low excess air coefficient, high boiler efficiency (1-2% higher than traditional products). And furnace and convection heating surface are not prone to agglomeration.<br />
2. Boiler's heating surface has a reasonable structural layout, with convection heating surface not easy to accumulate dust. It can work continuously &#38; stably for longer periods when compared to similar products.<br />
3. Reasonable proportioned secondary air controls the furnace temperature, makes initial NOx emission concentration of the boiler lower.<br />
4. With compact structure, small covering area，short installation period, quick and convenient installation, it has lower boiler room construction cost than traditional products.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/">SZL Double-drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Double-drum Corner Tube Biomass Steam Boiler<br />
<strong>Product Model: </strong>SZL Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 6t/h≤D≤20t/h; P≤3.82MPa;</p>
<h2><strong>8t/h ~20t/h Double-drum Corner Tube Biomass Steam Boiler</strong></h2>
<p>&nbsp;</p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>SZL8</th>
<th>SZL10</th>
<th>SZL15</th>
<th>SZL20</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="4">Single-drum horizontal fire tube/water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>8</td>
<td>10</td>
<td>15</td>
<td>20</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>20/104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥86</td>
<td>≥88</td>
<td>≥88</td>
<td>≥88</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="4">Biomass pellets (chain grate);<br />
Loose biomass like forest residues, wood chips, etc. (reciprocating grate)</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>392.7</td>
<td>483.2</td>
<td>831.2</td>
<td>939.5</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>12.5</td>
<td>13.2</td>
<td>14.1</td>
<td>14.9</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤140</td>
<td>≤110</td>
<td>≤110</td>
<td>≤110</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="4">Slightly negative pressure grate firing</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="4">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>8130x3230x3700</td>
<td>8240x3340x3740</td>
<td>11500x3450x6315</td>
<td>12370x3370x8580</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>11600x5970x6120</td>
<td>12910x6650x6180</td>
<td>14300x6780x7720</td>
<td>14870x7800x10180</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN150</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>DN50+DN80</td>
<td>2xDN80</td>
<td>DN150+DN40</td>
<td>2xDN100</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Biomass feeding system</td>
<td colspan="4">
<h5>Customized for 8t/h ~20t/h Double-drum Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Ash discharge system</td>
<td colspan="4">Scraper ash remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="4">Customized (Normally by manual)</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="4">Customized, water quality standard GB1576</td>
</tr>
<tr>
<td colspan="2">Dust removal system (multi-tube / cyclone / bag filter)</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td colspan="2">In-furnace SNCR/ex-furnace SCR<br />
desulfurization and denitrification systems</td>
<td colspan="4">To be negotiated according to local environmental protection requirements</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>8-10</td>
<td>10-12</td>
<td>15-20</td>
<td>20-25</td>
</tr>
<tr>
<td>Head(m)</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>8-10</td>
<td>10-12</td>
<td>15-20</td>
<td>20-25</td>
</tr>
<tr>
<td>Head(m)</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="4">Customized (3 standard choices: high, medium &amp; basic)</td>
</tr>
<tr>
<td rowspan="2">Primary air fan</td>
<td>Flow (Nm³/h)</td>
<td>9520</td>
<td>12138</td>
<td>14994</td>
<td>24276</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2897</td>
<td>2955</td>
<td>3251</td>
<td>3576</td>
</tr>
<tr>
<td rowspan="2">Secondary air fan</td>
<td>Flow (Nm³/h)</td>
<td>2856</td>
<td>3641</td>
<td>4498</td>
<td>7283</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3326</td>
<td>3393</td>
<td>3563</td>
<td>3919</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (Nm³/h)</td>
<td>16850</td>
<td>17187</td>
<td>26539</td>
<td>34374</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3890</td>
<td>4084</td>
<td>4288</td>
<td>4717</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="4">G-type fixed-rotary type / Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="4">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/">SZL Double-drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DZL Single Drum Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 03:59:03 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=916</guid>

					<description><![CDATA[<p>1. Boiler proper adopts full membrane wall structure and light insulation material, with less air leakage &#38; low excess air coefficient, high boiler efficiency (1-2% higher than traditional products). And furnace and convection heating surface are not prone to agglomeration.<br />
2. Boiler's heating surface has a reasonable structural layout, with convection heating surface not easy to accumulate dust. It can work continuously &#38; stably for longer periods when compared to similar products.<br />
3. Reasonable proportioned secondary air controls the furnace temperature, makes initial NOx emission concentration of the boiler lower.<br />
4. With compact structure, small covering area，short installation period, quick and convenient installation, it has lower boiler room construction cost than traditional products.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/">DZL Single Drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Single Drum Corner Tube Biomass Steam Boiler<br />
<strong>Product Model:</strong> DZL Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 2t/h≤D≤10t/h; P≤3.82MPa;</p>
<h2><strong>2t/h ~ 6t/h Single Drum Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DZL2</th>
<th>DZL4</th>
<th>DZL6</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="3">Single-drum horizontal fire tube/water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>2</td>
<td>4</td>
<td>6</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20/104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥86</td>
<td>≥86</td>
<td>≥86</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="3">Biomass pellets (chain grate)<br />
Loose biomass like forest residues, wood chips, etc. (reciprocating grate)</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>80.6</td>
<td>154.2</td>
<td>252.5</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>4.8</td>
<td>7.5</td>
<td>9.75</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤140</td>
<td>≤140</td>
<td>≤140</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="3">Slightly negative pressure grate firing</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="3">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>5700×2210×33300</td>
<td>6170x2980x3500</td>
<td>7600x2980x3560</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>8900×3980×4720</td>
<td>8620x4320x5950</td>
<td>11200x4650x51200</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN65</td>
<td>DN100</td>
<td>DN125</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN40</td>
<td>2xDN50</td>
<td>DN50+DN80</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN25</td>
<td>DN40</td>
<td>DN50</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Biomass feeding system</td>
<td colspan="3">
<h5>Customized for 2t/h ~ 6t/h Single Drum Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Ash discharge system</td>
<td colspan="3">Scraper ash remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="3">Customized (Normally by manual)</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="3">Customized, water quality standard GB1576</td>
</tr>
<tr>
<td colspan="2">Dust removal system (multi-tube / cyclone / bag filter)</td>
<td colspan="3">Customized</td>
</tr>
<tr>
<td colspan="2">In-furnace SNCR/ex-furnace SCR<br />
desulfurization and denitrification systems</td>
<td colspan="3">To be negotiated according to local environmental protection requirements</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>2-4</td>
<td>4-6</td>
<td>6-8</td>
</tr>
<tr>
<td>Head(m)</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>2-4</td>
<td>2-4</td>
<td>6-8</td>
</tr>
<tr>
<td>Head(m)</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="3">Customized (3 standard choices: high, medium &amp; basic)</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow (Nm³/h)</td>
<td>2380</td>
<td>4760</td>
<td>7140</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2600</td>
<td>2652</td>
<td>2705</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan</td>
<td>Flow (Nm³/h)</td>
<td>715</td>
<td>1430</td>
<td>2142</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2900</td>
<td>2958</td>
<td>3017</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (Nm³/h)</td>
<td>3370</td>
<td>6740</td>
<td>10110</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3200</td>
<td>3360</td>
<td>3528</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="3">G-type fixed-rotary type / Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="3">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/">DZL Single Drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DHW Vertical Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 00:07:16 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=913</guid>

					<description><![CDATA[<p>1. Wide fuel adaptability, suitable for various types of biomass fuels. Chain or reciprocating grates can be selected according to fuel characteristics. Fuels with moisture content ≤50% can be stably and fully burned. It has high fuel burnout rate, low ash carbon content and high boiler efficiency.<br />
2. Low-pressure economizer is optional to the boiler system, it can further reduce the exhaust gas temperature and improve boiler thermal efficiency, which can be 3-5% higher than similar products.<br />
3. Furnace chamber has big space, it adopts novel combustion technology combining layer combustion with chamber combustion. Through unique coordination technique between boiler arch &#38; fuel wind, rationally organized furnace air dynamic field and flue gas temperature fields, it can control the furnace temperature effectively, achieve full combustion of volatiles &#38; three-level low-nitrogen combustion technology of fuel, air and flue gas at the same time. Boiler's initial NOx emission is less than 150mg/m³, initial CO emissions is less than 100mg/m³, eliminating no black smoke.<br />
4. Unique empty load channel design ensures temperatures of flue gas entering the dense convective heating surface &#60;650℃,with coking eliminated, initial emission concentration of smoke &#38; dust ≤600mg/Nm³;<br />
5. The dense heating surface and equal flue gas velocity design reduces local resistance, saves system power consumption, and prevents ash accumulation due to low flue gas velocity at the end.<br />
6. Boiler has annual operating time more than 8,000 hours, with fast fire &#38; pressure rise, sufficient output, and 10% overload operating capacity.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/">DHW Vertical Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical Corner Tube Biomass Steam Boiler<br />
<strong>Product Model:</strong> DHW Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 10t/h≤D≤130t/h; P≤9.8MPa; T≤540 ℃</p>
<h2><strong>10t/h ~ 30t/h Vertical Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DHW10</th>
<th>DHW15</th>
<th>DHW20</th>
<th>DHW25</th>
<th>DHW30</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="5">Single-drum horizontal water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>10</td>
<td>15</td>
<td>20</td>
<td>25</td>
<td>30</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="5">Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>549.23</td>
<td>729.72</td>
<td>1035.62</td>
<td>1230.53</td>
<td>1470.24</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>11.2</td>
<td>14.8</td>
<td>16.5</td>
<td>17.6</td>
<td>21.5</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="5">Negative micro-pressure sliding combustion</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="5">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>6000×4310×8600</td>
<td>8170×3470×11500</td>
<td>8290×3760×12300</td>
<td>8320×3920×12500</td>
<td>10120×5730×17700</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>12000×6650×10640</td>
<td>11935×6500×15200</td>
<td>12140×6920×15700</td>
<td>12180×7150×15960</td>
<td>14180×7530×19700</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN100</td>
<td>2×DN125</td>
<td>2×DN150</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Ash Discharge System</td>
<td colspan="5">Chain-and-Flight Ash Remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="5">
<h5>Customized for 10t/h ~ 30t/h Vertical Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td colspan="2">Desulfurization and denitrification system</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow(m³/h)</td>
<td>10–12</td>
<td>15–18</td>
<td>20–24</td>
<td>25–30</td>
<td>30–36</td>
</tr>
<tr>
<td>Lift(m)</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow(m³/h)</td>
<td>10–12</td>
<td>15–18</td>
<td>20–24</td>
<td>25–30</td>
<td>30–36</td>
</tr>
<tr>
<td>Lift(m)</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow(m³/h)</td>
<td>11800</td>
<td>17700</td>
<td>23600</td>
<td>29500</td>
<td>35400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3200</td>
<td>3264</td>
<td>3329</td>
<td>3396</td>
<td>3464</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan (FGR)</td>
<td>Flow(m³/h)</td>
<td>4175</td>
<td>6263</td>
<td>8350</td>
<td>10438</td>
<td>12525</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3700</td>
<td>3774</td>
<td>3849</td>
<td>3926</td>
<td>4005</td>
</tr>
<tr>
<td rowspan="2">Tertiary Air Fan</td>
<td>Flow(m³/h)</td>
<td>7000</td>
<td>10500</td>
<td>14000</td>
<td>17500</td>
<td>21000</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3700</td>
<td>3774</td>
<td>3849</td>
<td>3926</td>
<td>4005</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow(m³/h)</td>
<td>16700</td>
<td>25050</td>
<td>33400</td>
<td>41750</td>
<td>50100</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4000</td>
<td>4200</td>
<td>4410</td>
<td>4631</td>
<td>4862</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="5">G-type fixed-rotary type/ Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="5">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>40t/h ~ 75t/h Vertical Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DHW40</th>
<th>DHW50</th>
<th>DHW60</th>
<th>DHW75</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="4">Single-drum horizontal water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>40</td>
<td>50</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="4">Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>1709.9</td>
<td>2312.56</td>
<td>2712.21</td>
<td>3287.65</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>23.3</td>
<td>28.5</td>
<td>29.8</td>
<td>33.6</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="4">Negative micro-pressure sliding combustion</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="4">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>11850×8000×21790</td>
<td>12350×8000×22280</td>
<td>13100×7800×24580</td>
<td>13920×8300×25920</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>16720×10500×23790</td>
<td>17220×10720×24280</td>
<td>26700×11800×26580</td>
<td>27950×12600×27950</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN250</td>
<td>DN300</td>
<td>DN350</td>
<td>DN350</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN150</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN250</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN125</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Ash Discharge System</td>
<td colspan="5">Chain-and-Flight Ash Remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="4">
<h5>Customized for 40t/h ~ 75t/h Vertical Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td colspan="2">Desulfurization &amp; denitrification system</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (m³/h)</td>
<td>40–48</td>
<td>50–62</td>
<td>60–72</td>
<td>60–72</td>
</tr>
<tr>
<td>Lift (m)</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (m³/h)</td>
<td>40–48</td>
<td>50–62</td>
<td>60–72</td>
<td>60–72</td>
</tr>
<tr>
<td>Lift (m)</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow (m³/h)</td>
<td>47200</td>
<td>59000</td>
<td>70800</td>
<td>94400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3533</td>
<td>3886</td>
<td>4275</td>
<td>4703</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan (FGR)</td>
<td>Flow (m³/h)</td>
<td>16700</td>
<td>20875</td>
<td>25050</td>
<td>33400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4085</td>
<td>4167</td>
<td>4583</td>
<td>5042</td>
</tr>
<tr>
<td rowspan="2">Tertiary Air Fan</td>
<td>Flow (m³/h)</td>
<td>28000</td>
<td>35000</td>
<td>42000</td>
<td>56000</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4085</td>
<td>4494</td>
<td>4943</td>
<td>5437</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (m³/h)</td>
<td>66800</td>
<td>83500</td>
<td>100200</td>
<td>133600</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>5105</td>
<td>5360</td>
<td>5896</td>
<td>6486</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="4">G-type fixed-rotary type/ Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack (mm)</td>
<td colspan="4">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/">DHW Vertical Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
