<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Industrial Gas and Biomass Boilers- Brit Industrial Boilers</title>
	<atom:link href="https://britboiler.com/industrial-gas-biomass-boilers/feed/" rel="self" type="application/rss+xml" />
	<link>https://britboiler.com/product/</link>
	<description>Gas &#38; Biomass Steam Boilers</description>
	<lastBuildDate>Tue, 09 Dec 2025 02:45:11 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://britboiler.com/wp-content/uploads/2025/11/cropped-Brit-Thermal-Energy-Site-Logo-1-32x32.png</url>
	<title>Industrial Gas and Biomass Boilers- Brit Industrial Boilers</title>
	<link>https://britboiler.com/product/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>WNS Three-Pass Fire-Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 08:56:16 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=929</guid>

					<description><![CDATA[<p>1. Full-waveform furnace structure avoids cracking caused by stress concentration, thereby extending boiler's service life.<br />
2. Unique "welding &#38; expansion" process prevents subcooled boiling at the tube and plate welds, thus ensuring a safe, reliable and stable boiler operation.<br />
3. Fire-tube adopts special threaded tube to reduce smoke flow resistance and enhance the heat transfer effect.<br />
4. Frameless outer-clad structure &#38; entire coating with heat-resistant paint minimize the heat losses.<br />
5. Large combustion chamber design enables fuel to burn more fully and thoroughly at a relatively low furnace volume heat load, nitrogen oxides are less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/">WNS Three-Pass Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Three-Pass Fire-Tube Gas Steam Boiler<br />
Product Model: WNS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, meanwhile, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 1t/h≤D≤20t/h; P≤1.25Mpa</p>
<h2><strong>1t/h ~ 5t/h Three-Pass Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>WNS1-1.25-Q</th>
<th>WNS2-1.25-Q</th>
<th>WNS3-1.25-Q</th>
<th>WNS4-1.25-Q</th>
<th>WNS5-1.25-Q</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>1</td>
<td>2</td>
<td>3</td>
<td>4</td>
<td>5</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>20</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>3.6</td>
<td>5.0</td>
<td>7.5</td>
<td>11.0</td>
<td>12</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>5.5</td>
<td>6</td>
<td>11</td>
<td>12.5</td>
<td>15</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>3700×1800×2100</td>
<td>4400×2000×2300</td>
<td>4700×2300×2900</td>
<td>5200×2450×2850</td>
<td>5450×2550×2950</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN50</td>
<td>DN65</td>
<td>DN80</td>
<td>DN100</td>
<td>DN100</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN50</td>
<td>2×DN65</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN25</td>
<td>DN32</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>6t/h ~ 20t/h Three-Pass Fire-Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model Parameters</th>
<th>WNS6-1.25-Q</th>
<th>WNS8-1.25-Q</th>
<th>WNS10-1.25-Q</th>
<th>WNS15-1.25-Q</th>
<th>WNS20-1.25-Q</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>6</td>
<td>8</td>
<td>10</td>
<td>15</td>
<td>20</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
<td>193</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>13.85</td>
<td>20</td>
<td>26</td>
<td>28.2</td>
<td>37.3</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
<td>≤100</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>20/18</td>
<td>24</td>
<td>27</td>
<td>40</td>
<td>52.5</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>5900×2700×3200</td>
<td>6500×2950×3450</td>
<td>7100×3200×3600</td>
<td>7700×4600×5000</td>
<td>8850×3700×4055</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>7900×3800×4650</td>
<td>8534×3800×4650</td>
<td>8650×4650×5000</td>
<td>9200×4660×5100</td>
<td>9900×4850×5600</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN125</td>
<td>DN150</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN65</td>
<td>2×DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN100</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
<td>DN80</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
<td>2×DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/wns-three-pass-fire-tube-gas-steam-boiler/">WNS Three-Pass Fire-Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SZS Low Nitrogen Water Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 07:33:37 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=925</guid>

					<description><![CDATA[<p>1. Water circulation utilizes a combination of forced and natural circulation；Boiler's internal devices are rationally arranged to ensure the medium flowing in the tubes of a single loop will not cause steam and water to boil, with water velocity reasonable, safe and reliable.<br />
2. Flue gas is controlled at around 10m/s, Adjacent tubes in convection tube bundles are connected with stainless steel flat bars to increase tube rigidity and prevent vibration during flue gas scouring. Guide plates are installed at flue bends to eliminate vibration during boiler operation.<br />
3. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
4. Boiler is surrounded by membrane type water-cooled walls on all sides, providing excellent sealing and preventing flue gas leakage, reducing heat loss and improving boiler efficiency.<br />
5. With multiple layers of lightweight insulation cotton overlapped staggeredly, entire coating with heat-resistant paint, it makes heat dissipation loss≤0.15%. Membrane walls around the boiler form a large D-shaped furnace, and furnace volume heat load is ≤500kw,  which is more conducive to low-nitrogen emissions with nitrogen oxides less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/">SZS Low Nitrogen Water Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Low Nitrogen Water Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> SZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 14MW≤Q≤29MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model /<br />
Parameters</th>
<th>SZS14-1.25/115/70-Q</th>
<th>SZS17.5-1.25/115/70-Q</th>
<th>SZS21-1.25/115/70-Q</th>
<th>SZS29-1.6/130/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>14</td>
<td>17.5</td>
<td>21</td>
<td>29</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>115</td>
<td>115</td>
<td>115</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>12.7</td>
<td>16.4</td>
<td>19.1</td>
<td>23.6</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="4">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>45</td>
<td>50</td>
<td>62</td>
<td>70</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>9820×3780×3850</td>
<td>9820×4070×4000</td>
<td>10700×4200×4000</td>
<td>13400×4200×4200</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>11240×6465×5085</td>
<td>11240×6765×5235</td>
<td>12120×7000×5330</td>
<td>14840×7215×5535</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300(2×DN200+DN150)</td>
</tr>
<tr>
<td>Backwater valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>DN150+DN50</td>
<td>DN150+DN100</td>
<td>20×DN150</td>
<td>20×DN150</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/szs-low-nitrogen-water-tube-gas-hot-water-boiler/">SZS Low Nitrogen Water Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 07:06:34 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=922</guid>

					<description><![CDATA[<p>1. Water circulation utilizes a combination of forced and natural circulation；Boiler's internal devices are rationally arranged to ensure the medium flowing in the tubes of a single loop will not cause steam and water to boil, with water velocity reasonable, safe and reliable.<br />
2. Flue gas is controlled at around 10m/s, Adjacent tubes in convection tube bundles are connected with stainless steel flat bars to increase tube rigidity and prevent vibration during flue gas scouring. Guide plates are installed at flue bends to eliminate vibration during boiler operation.<br />
3. Economizer (condenser) adopts patented technology with independent intellectual property rights, taking into account both heat transfer efficiency and operation resistance;<br />
4. Boiler is surrounded by membrane type water-cooled walls on all sides, providing excellent sealing and preventing flue gas leakage, reducing heat loss and improving boiler efficiency.<br />
5. With multiple layers of lightweight insulation cotton overlapped staggeredly, entire coating with heat-resistant paint, it makes heat dissipation loss≤0.15%. Membrane walls around the boiler form a large D-shaped furnace, and furnace volume heat load is ≤500kw, which is more conducive to low-nitrogen emissions with nitrogen oxides less than 30mg/Nm³.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/">SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Low Nitrogen Condensing Water Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> SZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, meanwhile, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> D≤40t/h; P≤2.5MPa; T≤450℃</p>
<h2><strong>2t/h &#8211; 10t/h Low Nitrogen Condensing Water Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>SZS2</th>
<th>SZS3</th>
<th>SZS4</th>
<th>SZS6</th>
<th>SZS10</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>2</td>
<td>3</td>
<td>4</td>
<td>6</td>
<td>10</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>2.5</td>
<td>2.5</td>
<td>2.5</td>
<td>2.5</td>
<td>1.25/1.6/2.5</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>226</td>
<td>226</td>
<td>226</td>
<td>226</td>
<td>194/204/226</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td>/</td>
<td>/</td>
<td>/</td>
<td>/</td>
<td>/</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>3.9</td>
<td>4.6</td>
<td>6.9</td>
<td>7.6</td>
<td>10.2</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>9.5</td>
<td>11</td>
<td>13</td>
<td>19</td>
<td>30</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>4200×2600×3300</td>
<td>4800×2900×3300</td>
<td>5300×2900×3000</td>
<td>6200×2900×3700</td>
<td>6900×3300×3700</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>4750×4000×3300</td>
<td>5400×4300×3300</td>
<td>5900×4990×4025</td>
<td>6800×4990×4500</td>
<td>9075×5295×4500</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
<td>DN125</td>
<td>DN150</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN40</td>
<td>2×DN65</td>
<td>2×DN80</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN50</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN40</td>
<td>DN40</td>
<td>DN40</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, We can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>15t/h &#8211; 40t/h Low Nitrogen Condensing Water Tube Gas Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model<br />
Parameters</th>
<th>SZS15</th>
<th>SZS20</th>
<th>SZS25</th>
<th>SZS30</th>
<th>SZS35</th>
<th>SZS40</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>15</td>
<td>20</td>
<td>25</td>
<td>30</td>
<td>35</td>
<td>40</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
<td>1.25/1.6/2.5</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
<td>194/204/226</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="6">≤450</td>
</tr>
<tr>
<td>Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>13</td>
<td>14.2</td>
<td>16.4</td>
<td>20</td>
<td>25</td>
<td>27</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="6">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>34</td>
<td>46</td>
<td>50</td>
<td>60</td>
<td>65</td>
<td>85</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>7900×3660×3850</td>
<td>8900×4000×3900</td>
<td>10050×4200×4100</td>
<td>11700×4200×4200</td>
<td>12000×4200×4200</td>
<td>13500×4500×4200</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>9320×6400×4725</td>
<td>11000×6200×4760</td>
<td>1360×6855×4590</td>
<td>3570×6365×5015</td>
<td>5480×6845×6070</td>
<td>15500×8400×6200</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
<td>DN250</td>
</tr>
<tr>
<td>Safety valve</td>
<td>DN80, DN100</td>
<td>2×DN100</td>
<td>DN100+DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN100</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, We can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/szs-low-nitrogen-condensing-water-tube-gas-steam-boiler/">SZS Low Nitrogen Condensing Water Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SZL Double-drum Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 05:50:59 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=918</guid>

					<description><![CDATA[<p>1. Boiler proper adopts full membrane wall structure and light insulation material, with less air leakage &#38; low excess air coefficient, high boiler efficiency (1-2% higher than traditional products). And furnace and convection heating surface are not prone to agglomeration.<br />
2. Boiler's heating surface has a reasonable structural layout, with convection heating surface not easy to accumulate dust. It can work continuously &#38; stably for longer periods when compared to similar products.<br />
3. Reasonable proportioned secondary air controls the furnace temperature, makes initial NOx emission concentration of the boiler lower.<br />
4. With compact structure, small covering area，short installation period, quick and convenient installation, it has lower boiler room construction cost than traditional products.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/">SZL Double-drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Double-drum Corner Tube Biomass Steam Boiler<br />
<strong>Product Model: </strong>SZL Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 6t/h≤D≤20t/h; P≤3.82MPa;</p>
<h2><strong>8t/h ~20t/h Double-drum Corner Tube Biomass Steam Boiler</strong></h2>
<p>&nbsp;</p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>SZL8</th>
<th>SZL10</th>
<th>SZL15</th>
<th>SZL20</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="4">Single-drum horizontal fire tube/water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>8</td>
<td>10</td>
<td>15</td>
<td>20</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>20/104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥86</td>
<td>≥88</td>
<td>≥88</td>
<td>≥88</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="4">Biomass pellets (chain grate);<br />
Loose biomass like forest residues, wood chips, etc. (reciprocating grate)</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>392.7</td>
<td>483.2</td>
<td>831.2</td>
<td>939.5</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>12.5</td>
<td>13.2</td>
<td>14.1</td>
<td>14.9</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤140</td>
<td>≤110</td>
<td>≤110</td>
<td>≤110</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="4">Slightly negative pressure grate firing</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="4">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>8130x3230x3700</td>
<td>8240x3340x3740</td>
<td>11500x3450x6315</td>
<td>12370x3370x8580</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>11600x5970x6120</td>
<td>12910x6650x6180</td>
<td>14300x6780x7720</td>
<td>14870x7800x10180</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN150</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>DN50+DN80</td>
<td>2xDN80</td>
<td>DN150+DN40</td>
<td>2xDN100</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN50</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Biomass feeding system</td>
<td colspan="4">
<h5>Customized for 8t/h ~20t/h Double-drum Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Ash discharge system</td>
<td colspan="4">Scraper ash remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="4">Customized (Normally by manual)</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="4">Customized, water quality standard GB1576</td>
</tr>
<tr>
<td colspan="2">Dust removal system (multi-tube / cyclone / bag filter)</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td colspan="2">In-furnace SNCR/ex-furnace SCR<br />
desulfurization and denitrification systems</td>
<td colspan="4">To be negotiated according to local environmental protection requirements</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>8-10</td>
<td>10-12</td>
<td>15-20</td>
<td>20-25</td>
</tr>
<tr>
<td>Head(m)</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>8-10</td>
<td>10-12</td>
<td>15-20</td>
<td>20-25</td>
</tr>
<tr>
<td>Head(m)</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="4">Customized (3 standard choices: high, medium &amp; basic)</td>
</tr>
<tr>
<td rowspan="2">Primary air fan</td>
<td>Flow (Nm³/h)</td>
<td>9520</td>
<td>12138</td>
<td>14994</td>
<td>24276</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2897</td>
<td>2955</td>
<td>3251</td>
<td>3576</td>
</tr>
<tr>
<td rowspan="2">Secondary air fan</td>
<td>Flow (Nm³/h)</td>
<td>2856</td>
<td>3641</td>
<td>4498</td>
<td>7283</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3326</td>
<td>3393</td>
<td>3563</td>
<td>3919</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (Nm³/h)</td>
<td>16850</td>
<td>17187</td>
<td>26539</td>
<td>34374</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3890</td>
<td>4084</td>
<td>4288</td>
<td>4717</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="4">G-type fixed-rotary type / Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="4">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/szl-double-drum-corner-tube-biomass-steam-boiler/">SZL Double-drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DZL Single Drum Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 03:59:03 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=916</guid>

					<description><![CDATA[<p>1. Boiler proper adopts full membrane wall structure and light insulation material, with less air leakage &#38; low excess air coefficient, high boiler efficiency (1-2% higher than traditional products). And furnace and convection heating surface are not prone to agglomeration.<br />
2. Boiler's heating surface has a reasonable structural layout, with convection heating surface not easy to accumulate dust. It can work continuously &#38; stably for longer periods when compared to similar products.<br />
3. Reasonable proportioned secondary air controls the furnace temperature, makes initial NOx emission concentration of the boiler lower.<br />
4. With compact structure, small covering area，short installation period, quick and convenient installation, it has lower boiler room construction cost than traditional products.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/">DZL Single Drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Single Drum Corner Tube Biomass Steam Boiler<br />
<strong>Product Model:</strong> DZL Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 2t/h≤D≤10t/h; P≤3.82MPa;</p>
<h2><strong>2t/h ~ 6t/h Single Drum Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DZL2</th>
<th>DZL4</th>
<th>DZL6</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="3">Single-drum horizontal fire tube/water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>2</td>
<td>4</td>
<td>6</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>203-250</td>
<td>203-250</td>
<td>203-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>20</td>
<td>20</td>
<td>20/104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥86</td>
<td>≥86</td>
<td>≥86</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="3">Biomass pellets (chain grate)<br />
Loose biomass like forest residues, wood chips, etc. (reciprocating grate)</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>80.6</td>
<td>154.2</td>
<td>252.5</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>4.8</td>
<td>7.5</td>
<td>9.75</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤140</td>
<td>≤140</td>
<td>≤140</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="3">Slightly negative pressure grate firing</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="3">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>5700×2210×33300</td>
<td>6170x2980x3500</td>
<td>7600x2980x3560</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>8900×3980×4720</td>
<td>8620x4320x5950</td>
<td>11200x4650x51200</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN65</td>
<td>DN100</td>
<td>DN125</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN40</td>
<td>2xDN50</td>
<td>DN50+DN80</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN25</td>
<td>DN40</td>
<td>DN50</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Biomass feeding system</td>
<td colspan="3">
<h5>Customized for 2t/h ~ 6t/h Single Drum Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Ash discharge system</td>
<td colspan="3">Scraper ash remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="3">Customized (Normally by manual)</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="3">Customized, water quality standard GB1576</td>
</tr>
<tr>
<td colspan="2">Dust removal system (multi-tube / cyclone / bag filter)</td>
<td colspan="3">Customized</td>
</tr>
<tr>
<td colspan="2">In-furnace SNCR/ex-furnace SCR<br />
desulfurization and denitrification systems</td>
<td colspan="3">To be negotiated according to local environmental protection requirements</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>2-4</td>
<td>4-6</td>
<td>6-8</td>
</tr>
<tr>
<td>Head(m)</td>
<td>50-60</td>
<td>50-60</td>
<td>50-60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (Nm³/h)</td>
<td>2-4</td>
<td>2-4</td>
<td>6-8</td>
</tr>
<tr>
<td>Head(m)</td>
<td>168-200</td>
<td>168-200</td>
<td>168-200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="3">Customized (3 standard choices: high, medium &amp; basic)</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow (Nm³/h)</td>
<td>2380</td>
<td>4760</td>
<td>7140</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2600</td>
<td>2652</td>
<td>2705</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan</td>
<td>Flow (Nm³/h)</td>
<td>715</td>
<td>1430</td>
<td>2142</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>2900</td>
<td>2958</td>
<td>3017</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (Nm³/h)</td>
<td>3370</td>
<td>6740</td>
<td>10110</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3200</td>
<td>3360</td>
<td>3528</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="3">G-type fixed-rotary type / Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="3">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dzl-single-drum-corner-tube-biomass-steam-boiler/">DZL Single Drum Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DHW Vertical Corner Tube Biomass Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Tue, 25 Nov 2025 00:07:16 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=913</guid>

					<description><![CDATA[<p>1. Wide fuel adaptability, suitable for various types of biomass fuels. Chain or reciprocating grates can be selected according to fuel characteristics. Fuels with moisture content ≤50% can be stably and fully burned. It has high fuel burnout rate, low ash carbon content and high boiler efficiency.<br />
2. Low-pressure economizer is optional to the boiler system, it can further reduce the exhaust gas temperature and improve boiler thermal efficiency, which can be 3-5% higher than similar products.<br />
3. Furnace chamber has big space, it adopts novel combustion technology combining layer combustion with chamber combustion. Through unique coordination technique between boiler arch &#38; fuel wind, rationally organized furnace air dynamic field and flue gas temperature fields, it can control the furnace temperature effectively, achieve full combustion of volatiles &#38; three-level low-nitrogen combustion technology of fuel, air and flue gas at the same time. Boiler's initial NOx emission is less than 150mg/m³, initial CO emissions is less than 100mg/m³, eliminating no black smoke.<br />
4. Unique empty load channel design ensures temperatures of flue gas entering the dense convective heating surface &#60;650℃,with coking eliminated, initial emission concentration of smoke &#38; dust ≤600mg/Nm³;<br />
5. The dense heating surface and equal flue gas velocity design reduces local resistance, saves system power consumption, and prevents ash accumulation due to low flue gas velocity at the end.<br />
6. Boiler has annual operating time more than 8,000 hours, with fast fire &#38; pressure rise, sufficient output, and 10% overload operating capacity.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/">DHW Vertical Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical Corner Tube Biomass Steam Boiler<br />
<strong>Product Model:</strong> DHW Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 10t/h≤D≤130t/h; P≤9.8MPa; T≤540 ℃</p>
<h2><strong>10t/h ~ 30t/h Vertical Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DHW10</th>
<th>DHW15</th>
<th>DHW20</th>
<th>DHW25</th>
<th>DHW30</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="5">Single-drum horizontal water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>10</td>
<td>15</td>
<td>20</td>
<td>25</td>
<td>30</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="5">Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>549.23</td>
<td>729.72</td>
<td>1035.62</td>
<td>1230.53</td>
<td>1470.24</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>11.2</td>
<td>14.8</td>
<td>16.5</td>
<td>17.6</td>
<td>21.5</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="5">Negative micro-pressure sliding combustion</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="5">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>6000×4310×8600</td>
<td>8170×3470×11500</td>
<td>8290×3760×12300</td>
<td>8320×3920×12500</td>
<td>10120×5730×17700</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>12000×6650×10640</td>
<td>11935×6500×15200</td>
<td>12140×6920×15700</td>
<td>12180×7150×15960</td>
<td>14180×7530×19700</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN150</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN100</td>
<td>2×DN125</td>
<td>2×DN150</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN50</td>
<td>DN65</td>
<td>DN65</td>
<td>DN80</td>
<td>DN80</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Ash Discharge System</td>
<td colspan="5">Chain-and-Flight Ash Remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="5">
<h5>Customized for 10t/h ~ 30t/h Vertical Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td colspan="2">Desulfurization and denitrification system</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow(m³/h)</td>
<td>10–12</td>
<td>15–18</td>
<td>20–24</td>
<td>25–30</td>
<td>30–36</td>
</tr>
<tr>
<td>Lift(m)</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow(m³/h)</td>
<td>10–12</td>
<td>15–18</td>
<td>20–24</td>
<td>25–30</td>
<td>30–36</td>
</tr>
<tr>
<td>Lift(m)</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="5">Customized</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow(m³/h)</td>
<td>11800</td>
<td>17700</td>
<td>23600</td>
<td>29500</td>
<td>35400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3200</td>
<td>3264</td>
<td>3329</td>
<td>3396</td>
<td>3464</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan (FGR)</td>
<td>Flow(m³/h)</td>
<td>4175</td>
<td>6263</td>
<td>8350</td>
<td>10438</td>
<td>12525</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3700</td>
<td>3774</td>
<td>3849</td>
<td>3926</td>
<td>4005</td>
</tr>
<tr>
<td rowspan="2">Tertiary Air Fan</td>
<td>Flow(m³/h)</td>
<td>7000</td>
<td>10500</td>
<td>14000</td>
<td>17500</td>
<td>21000</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3700</td>
<td>3774</td>
<td>3849</td>
<td>3926</td>
<td>4005</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow(m³/h)</td>
<td>16700</td>
<td>25050</td>
<td>33400</td>
<td>41750</td>
<td>50100</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4000</td>
<td>4200</td>
<td>4410</td>
<td>4631</td>
<td>4862</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="5">G-type fixed-rotary type/ Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack(mm)</td>
<td colspan="5">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<h2><strong>40t/h ~ 75t/h Vertical Corner Tube Biomass Steam Boiler</strong></h2>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th colspan="2">Model Parameters</th>
<th>DHW40</th>
<th>DHW50</th>
<th>DHW60</th>
<th>DHW75</th>
</tr>
<tr>
<td colspan="2">Structure</td>
<td colspan="4">Single-drum horizontal water tube boiler</td>
</tr>
<tr>
<td colspan="2">Rated evaporation (T/H)</td>
<td>40</td>
<td>50</td>
<td>60</td>
<td>75</td>
</tr>
<tr>
<td colspan="2">Working pressure (MPa)</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
<td>1.25;1.6</td>
</tr>
<tr>
<td colspan="2">Steam temperature (saturated °C)</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
<td>194;204</td>
</tr>
<tr>
<td colspan="2">Slightly superheated steam temperature (℃)</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
<td>230-250</td>
</tr>
<tr>
<td colspan="2">Feed water temperature (℃)</td>
<td>104</td>
<td>104</td>
<td>104</td>
<td>104</td>
</tr>
<tr>
<td colspan="2">Boiler efficiency (%)</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
<td>≥90</td>
</tr>
<tr>
<td colspan="2">Design fuel</td>
<td colspan="4">Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw</td>
</tr>
<tr>
<td colspan="2">Heating area (M²)</td>
<td>1709.9</td>
<td>2312.56</td>
<td>2712.21</td>
<td>3287.65</td>
</tr>
<tr>
<td colspan="2">Full water capacity (M³)</td>
<td>23.3</td>
<td>28.5</td>
<td>29.8</td>
<td>33.6</td>
</tr>
<tr>
<td colspan="2">Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td colspan="2">Combustion mode</td>
<td colspan="4">Negative micro-pressure sliding combustion</td>
</tr>
<tr>
<td colspan="2">Applicable altitude (m)</td>
<td colspan="4">Areas with altitude less than 500 meters</td>
</tr>
<tr>
<td colspan="2">Dimensions of boiler proper (L×W×H) (mm)</td>
<td>11850×8000×21790</td>
<td>12350×8000×22280</td>
<td>13100×7800×24580</td>
<td>13920×8300×25920</td>
</tr>
<tr>
<td colspan="2">Dimensions after installation (L×W×H) (mm)</td>
<td>16720×10500×23790</td>
<td>17220×10720×24280</td>
<td>26700×11800×26580</td>
<td>27950×12600×27950</td>
</tr>
<tr>
<td colspan="2">Main steam valve diameter (mm)</td>
<td>DN250</td>
<td>DN300</td>
<td>DN350</td>
<td>DN350</td>
</tr>
<tr>
<td colspan="2">Safety valve diameter (mm)</td>
<td>2×DN150</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN250</td>
</tr>
<tr>
<td colspan="2">Water inlet diameter (mm)</td>
<td>DN80</td>
<td>2×DN80</td>
<td>2×DN100</td>
<td>2×DN125</td>
</tr>
<tr>
<td colspan="2">Blow-down diameter (mm)</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
<td>40;50</td>
</tr>
<tr>
<td colspan="2">Ash Discharge System</td>
<td colspan="5">Chain-and-Flight Ash Remover</td>
</tr>
<tr>
<td colspan="2">Ash disposal system</td>
<td colspan="4">
<h5>Customized for 40t/h ~ 75t/h Vertical Corner Tube Biomass Steam Boiler</h5>
</td>
</tr>
<tr>
<td colspan="2">Water treatment system</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td colspan="2">Desulfurization &amp; denitrification system</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td rowspan="2">Deaerator feed water pump</td>
<td>Flow (m³/h)</td>
<td>40–48</td>
<td>50–62</td>
<td>60–72</td>
<td>60–72</td>
</tr>
<tr>
<td>Lift (m)</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
<td>50–60</td>
</tr>
<tr>
<td rowspan="2">Boiler feed water pump</td>
<td>Flow (m³/h)</td>
<td>40–48</td>
<td>50–62</td>
<td>60–72</td>
<td>60–72</td>
</tr>
<tr>
<td>Lift (m)</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
<td>168–200</td>
</tr>
<tr>
<td colspan="2">Control cabinet</td>
<td colspan="4">Customized</td>
</tr>
<tr>
<td rowspan="2">Primary Air Fan</td>
<td>Flow (m³/h)</td>
<td>47200</td>
<td>59000</td>
<td>70800</td>
<td>94400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>3533</td>
<td>3886</td>
<td>4275</td>
<td>4703</td>
</tr>
<tr>
<td rowspan="2">Secondary Air Fan (FGR)</td>
<td>Flow (m³/h)</td>
<td>16700</td>
<td>20875</td>
<td>25050</td>
<td>33400</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4085</td>
<td>4167</td>
<td>4583</td>
<td>5042</td>
</tr>
<tr>
<td rowspan="2">Tertiary Air Fan</td>
<td>Flow (m³/h)</td>
<td>28000</td>
<td>35000</td>
<td>42000</td>
<td>56000</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>4085</td>
<td>4494</td>
<td>4943</td>
<td>5437</td>
</tr>
<tr>
<td rowspan="2">Induced draft fan</td>
<td>Flow (m³/h)</td>
<td>66800</td>
<td>83500</td>
<td>100200</td>
<td>133600</td>
</tr>
<tr>
<td>Pressure (Pa)</td>
<td>5105</td>
<td>5360</td>
<td>5896</td>
<td>6486</td>
</tr>
<tr>
<td colspan="2">Soot blower</td>
<td colspan="4">G-type fixed-rotary type/ Impulse type</td>
</tr>
<tr>
<td colspan="2">Dia. &amp; Height of stack (mm)</td>
<td colspan="4">According to the local environmental protection requirements / environment impact assessment report</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., as the design data may subject to changes without prior notice, thus the final design drawing shall prevail.<br />
2. In addition, we can design and manufacture boilers with other parameters according to customers&#8217; requirements.<br />
3. What&#8217;s more, we can also OEM boilers for you if needed, including boiler proper and other auxiliary equipment.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/biomass-steam-boiler/dhw-vertical-corner-tube-biomass-steam-boiler/">DHW Vertical Corner Tube Biomass Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 08:58:51 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=905</guid>

					<description><![CDATA[<p>1. Boiler proper utilizes self-supporting vertical corner tube structure, with high strength &#38;amp; stability, safe and reliable without shaking or surging.<br />
2. Hot water boiler has no drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.<br />
3. Hot water boiler utilizes forced circulation + natural circulation (auxiliary). Vertical layout offers a greater height difference than traditional products, ensuring safer water circulation.<br />
4. Large second-passage space provides ample heating surface arrangement in boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high efficiency.<br />
5. Equal flue gas velocity design for dense convection heating surfaces makes flue gas velocity rationally controlled, prevents shaking of the heating surface.<br />
6. Reserving sufficient space between densely heated surfaces for inspection &#38;amp; maintenance makes easy entry &#38;amp; exit of furnace &#38;amp; furnace chamber, making inspection &#38;amp; maintenance more convenient.<br />
7. Modular design, high assembly degree, short installation period, small base space, more suitable for large capacity boilers.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/">QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical (Modular) Corner Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> QXS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 29MW≤Q≤116MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>QXS29-1.6/130/70-Q (Modular)</th>
<th>QXS46-1.6/130/70-Q (Modular)</th>
<th>QXS58-1.6/130/70-Q (Modular)</th>
<th>QXS70-1.6/130/70-Q (Modular)</th>
<th>QXS116-1.6/130/70-Q (Modular)</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>29</td>
<td>46</td>
<td>58</td>
<td>70</td>
<td>116</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>25.6</td>
<td>38.7</td>
<td>41.5</td>
<td>49.7</td>
<td>61.4</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96.3</td>
<td>≥96.5</td>
<td>≥96.8</td>
<td>≥96.8</td>
<td>≥97.1</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="5">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>29.5</td>
<td>41.6</td>
<td>44.2</td>
<td>52.8</td>
<td>31.6</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>8.2×4×11.2</td>
<td>9.4×4.2×11.6</td>
<td>11.2×4.2×13.5</td>
<td>11.8×4.2×14.2</td>
<td>12.2×8.4×13.5</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>9.6×6.1×11.2</td>
<td>10.8×6.4×12.6</td>
<td>13.2×6.4×15.5</td>
<td>14.3×6.4×16.8</td>
<td>15×10.9×15.5</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN300</td>
<td>DN400</td>
<td>2×DN400</td>
</tr>
<tr>
<td>Backwater valve</td>
<td>DN300</td>
<td>DN300</td>
<td>DN350</td>
<td>DN400</td>
<td>DN500</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
<td>2×DN200</td>
<td>2×DN250</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-vertical-modular-corner-tube-gas-hot-water-boiler/">QXS Vertical (Modular) Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DHS Vertical (Modular) Corner Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 08:19:19 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=902</guid>

					<description><![CDATA[<p>1. Boiler proper utilizes self-supporting vertical corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.<br />
2. Steam boiler has a single drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.<br />
3. Steam boiler utilizes natural circulation + forced circulation (auxiliary). Vertical layout offers a greater height difference than traditional products, ensuring safer water circulation.<br />
4. Large second-passage space provides ample heating surface arrangement in boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high efficiency.<br />
5. Equal flue gas velocity design for dense convection heating surfaces makes flue gas velocity rationally controlled, prevents shaking of the heating surface.<br />
6. Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.<br />
7. Modular design, high assembly degree, short installation period, small base space, more suitable for large capacity boilers.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/">DHS Vertical (Modular) Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Vertical (Modular) Corner Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> DHS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 60t/h&lt;D≤160t/h; P≤9.8MPa; T≤540 ℃</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>DHS40 (Modular)</th>
<th>DHS50 (Modular)</th>
<th>DHS65 (Modular)</th>
<th>DHS75 (Modular)</th>
<th>DHS100 (Modular)</th>
<th>DHS130 (Modular)</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>40</td>
<td>50</td>
<td>65</td>
<td>75</td>
<td>100</td>
<td>130</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td colspan="6">1.25～9.8</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td colspan="6">194(1.25MPa) / 204(1.6MPa) / 226(2.5MPa) / 250(3.82MPa)</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="6">≤540</td>
</tr>
<tr>
<td>Rated feed water temperature (℃)</td>
<td colspan="6">104(P≤3.82MPa) / 128(P≤5.4MPa) / 157(P≤9.8MPa)</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>22.3</td>
<td>27.5</td>
<td>28.6</td>
<td>33.3</td>
<td>40.2</td>
<td>46.7</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99.2</td>
<td>≥99.2</td>
<td>≥99.2</td>
<td>≥99.3</td>
<td>≥99.5</td>
<td>≥99.7</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="6">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>30</td>
<td>37</td>
<td>42</td>
<td>45</td>
<td>53</td>
<td>65</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>8.6×4×12.4</td>
<td>11×4.1×13.2</td>
<td>11.2×4.2×15.9</td>
<td>11.6×4.2×16.5</td>
<td>14×4.3×20.5</td>
<td>10.6×8.3×15.5</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>10.2×5.5×13.2</td>
<td>12.4×7.7×14</td>
<td>12.7×7.8×16.8</td>
<td>13×8×17.3</td>
<td>15.5×9.6×21.3</td>
<td>12.2×10.8×16.3</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface<br />
diameter (mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300</td>
<td>DN300</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN250</td>
<td>1×DN250 / 1×DN300</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN100</td>
<td>DN100</td>
<td>DN125</td>
<td>DN125</td>
<td>DN150</td>
<td>DN150</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dhs-vertical-modular-corner-tube-gas-steam-boiler/">DHS Vertical (Modular) Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>QXS Horizontal Package Corner Tube Gas Hot Water Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 07:44:26 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=897</guid>

					<description><![CDATA[<ol>
<li>Boiler proper utilizes self-supporting horizontal corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.</li>
<li>Hot water boiler has no drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.</li>
<li>Hot water boiler utilizes forced circulation + natural circulation (auxiliary. Single drum layout offers a greater height difference than traditional products, ensuring safer water circulation.</li>
<li>Convection heating surface utilizes smooth tube + spiral fin tube structure, providing ample heating surface area in the boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high thermal efficiency.</li>
<li>Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.</li>
<li>Horizontal structure fully assembled before delivery with low shipping cost, less installation workload and short installation period.</li>
</ol>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/">QXS Horizontal Package Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> QXS Horizontal Package Corner Tube Gas Hot Water Boiler<br />
<strong>Product Model:</strong> QXS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 14MW≤Q≤58MW</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Model / Parameters</th>
<th>QXS14-1.25/115/70-Q</th>
<th>QXS17.5-1.25/115/70-Q</th>
<th>QXS21-1.25/115/70-Q</th>
<th>QXS29-1.6/130/70-Q</th>
<th>QXS35-1.6/130/70-Q</th>
<th>QXS46-1.6/130/70-Q</th>
<th>QXS58-1.6/130/70-Q</th>
</tr>
<tr>
<td>Rated thermal power (MW)</td>
<td>14</td>
<td>17.5</td>
<td>21</td>
<td>29</td>
<td>35</td>
<td>46</td>
<td>58</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td>1.25</td>
<td>1.25</td>
<td>1.25</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
<td>1.6</td>
</tr>
<tr>
<td>Rated outlet water temperature (℃)</td>
<td>115</td>
<td>115</td>
<td>115</td>
<td>130</td>
<td>130</td>
<td>130</td>
<td>130</td>
</tr>
<tr>
<td>Rated return water temperature (℃)</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
<td>70</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>16.7</td>
<td>18.9</td>
<td>23.2</td>
<td>25.6</td>
<td>26.1</td>
<td>28.2</td>
<td>31.5</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
<td>≥96</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
<td>≤90</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="7">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>43.6</td>
<td>46.8</td>
<td>59.8</td>
<td>73.2</td>
<td>82.7</td>
<td>91.1</td>
<td>98.9</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (m)</td>
<td>9000×3800<br />
×3300</td>
<td>10400×3900<br />
×3400</td>
<td>11500×4000<br />
×3500</td>
<td>12700×4200<br />
×3800</td>
<td>13500×5000<br />
×4200</td>
<td>15200×5200<br />
×4350</td>
<td>17500×5500<br />
×4600</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (m)</td>
<td>11000×6600<br />
×4900</td>
<td>12500×6800<br />
×5000</td>
<td>14300×6800<br />
×5500</td>
<td>15500×7000<br />
×6000</td>
<td>16500×8200<br />
×6200</td>
<td>18000×8500<br />
×6350</td>
<td>20000×9200<br />
×6600</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Outlet valve</td>
<td>DN250</td>
<td>DN250</td>
<td>2×DN200</td>
<td>2×DN200</td>
<td>2×DN250</td>
<td>2×DN250</td>
<td>2×DN300</td>
</tr>
<tr>
<td>Return Water Valve</td>
<td>DN250</td>
<td>DN250</td>
<td>DN300</td>
<td>DN300</td>
<td>DN300</td>
<td>DN350</td>
<td>DN400</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN100</td>
<td>DN100+DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-hot-water-boiler/qxs-horizontal-package-corner-tube-gas-hot-water-boiler/">QXS Horizontal Package Corner Tube Gas Hot Water Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DZS Horizontal Package Corner Tube Gas Steam Boiler</title>
		<link>https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/</link>
		
		<dc:creator><![CDATA[edward]]></dc:creator>
		<pubDate>Mon, 24 Nov 2025 04:03:00 +0000</pubDate>
				<guid isPermaLink="false">https://britboiler.com/?post_type=product&#038;p=894</guid>

					<description><![CDATA[<ol>
<li>Boiler proper utilizes self-supporting horizontal corner tube structure, with high strength &#38; stability, safe and reliable without shaking or surging.</li>
<li>Steam boiler has a single drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.</li>
<li>Steam boiler utilizes natural circulation + forced circulation (auxiliary). Single drum layout offers a greater height difference than traditional products, ensuring safer water circulation.</li>
<li>Convection heating surface utilizes smooth tube + spiral fin tube structure, providing ample heating surface area in the boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high thermal efficiency.</li>
<li>Reserving sufficient space between densely heated surfaces for inspection &#38; maintenance makes easy entry &#38; exit of furnace &#38; furnace chamber, making inspection &#38; maintenance more convenient.</li>
<li>Horizontal structure fully assembled before delivery with low shipping cost, less installation workload and short installation period.</li>
</ol>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/">DZS Horizontal Package Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></description>
										<content:encoded><![CDATA[<p><strong>Product Name:</strong> Horizontal Package Corner Tube Gas Steam Boiler<br />
<strong>Product Model:</strong> DZS Series<br />
<strong>HS Code:</strong> 84021900<br />
<strong>Manufacturing Standards:</strong> ASME/EU/GB<br />
<strong>Packing:</strong> Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.<br />
<strong>Application Range:</strong> 1t/h≤D≤60t/h; P≤3.82Mpa; T≤450℃</p>
<p><strong>Parameters</strong></p>
<table style="border-collapse: collapse; text-align: center;" border="1" cellspacing="0" cellpadding="6">
<tbody>
<tr style="color: #ffffff; background: #ff4d00;">
<th>Parameters / Model</th>
<th>DZS20</th>
<th>DZS25</th>
<th>DZS30</th>
<th>DZS35</th>
<th>DZS40</th>
<th>DZS50</th>
<th>DZS60</th>
</tr>
<tr>
<td>Rated evaporation (T/H)</td>
<td>20</td>
<td>25</td>
<td>30</td>
<td>35</td>
<td>40</td>
<td>50</td>
<td>60</td>
</tr>
<tr>
<td>Rated working pressure (MPa)</td>
<td colspan="7">1.25/1.6/2.5/3.82</td>
</tr>
<tr>
<td>Saturated steam temperature (℃)</td>
<td colspan="7">194/204/226/250</td>
</tr>
<tr>
<td>Superheated steam temperature (℃)</td>
<td colspan="7">≤450</td>
</tr>
<tr>
<td>Rated feed water temperature (℃)</td>
<td colspan="7">104</td>
</tr>
<tr>
<td>Full water capacity (m³)</td>
<td>10</td>
<td>12.5</td>
<td>15</td>
<td>17</td>
<td>19</td>
<td>24</td>
<td>27.8</td>
</tr>
<tr>
<td>Design thermal efficiency (%)</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
<td>≥99</td>
</tr>
<tr>
<td>Exhaust gas temperature (℃)</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
<td>≤65</td>
</tr>
<tr>
<td>Design fuel</td>
<td colspan="7">Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.</td>
</tr>
<tr>
<td>Transport weight of the largest component (t)</td>
<td>43.2</td>
<td>46.7</td>
<td>60.6</td>
<td>62.6</td>
<td>66.3</td>
<td>84</td>
<td>95</td>
</tr>
<tr>
<td>Dimensions of boiler proper (L×W×H) (mm)</td>
<td>9200×3800<br />
×3600</td>
<td>10800×3900<br />
×3700</td>
<td>12000×4200<br />
×4000</td>
<td>12600×4400<br />
×4000</td>
<td>13000×4600<br />
×4200</td>
<td>13500×4800<br />
×4200</td>
<td>13500×5500<br />
×4600</td>
</tr>
<tr>
<td>Dimensions after installation (L×W×H) (mm)</td>
<td>11400×6600<br />
×5100</td>
<td>12900×6800<br />
×5200</td>
<td>14500×7500<br />
×5500</td>
<td>15200×8600<br />
×5500</td>
<td>15500×8900<br />
×5700</td>
<td>16000×9900<br />
×5700</td>
<td>16000×10000<br />
×5900</td>
</tr>
<tr>
<th style="border: 1px solid #000; padding: 6px; text-align: center; background: #f5f5f5;" colspan="8">Interface diameter<br />
(mm)</th>
</tr>
<tr>
<td>Main steam valve</td>
<td>DN200</td>
<td>DN200</td>
<td>DN200</td>
<td>DN250</td>
<td>DN250</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Safety valve</td>
<td>2×DN100</td>
<td>2×DN125</td>
<td>2×DN125</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN150</td>
<td>2×DN200</td>
</tr>
<tr>
<td>Water inlet valve</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN80</td>
<td>DN100</td>
<td>DN100</td>
<td>DN125</td>
</tr>
<tr>
<td>Blowdown valve</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
<td>DN50</td>
</tr>
</tbody>
</table>
<p>Note:<br />
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.<br />
2. We can design and manufacture boilers with other parameters according to customers&#8217; requirements.</p>
<p><a href="https://britboiler.com/industrial-gas-biomass-boilers/gas-steam-boiler/dzs-package-corner-tube-gas-steam-boiler/">DZS Horizontal Package Corner Tube Gas Steam Boiler</a>最先出现在<a href="https://britboiler.com">Brit Industrial Boilers</a>。</p>
]]></content:encoded>
					
		
		
			</item>