首页 » Product » DHW Vertical Corner Tube Biomass Steam Boiler

DHW Vertical Corner Tube Biomass Steam Boiler

1. Wide fuel adaptability, suitable for various types of biomass fuels. Chain or reciprocating grates can be selected according to fuel characteristics. Fuels with moisture content ≤50% can be stably and fully burned. It has high fuel burnout rate, low ash carbon content and high boiler efficiency.
2. Low-pressure economizer is optional to the boiler system, it can further reduce the exhaust gas temperature and improve boiler thermal efficiency, which can be 3-5% higher than similar products.
3. Furnace chamber has big space, it adopts novel combustion technology combining layer combustion with chamber combustion. Through unique coordination technique between boiler arch & fuel wind, rationally organized furnace air dynamic field and flue gas temperature fields, it can control the furnace temperature effectively, achieve full combustion of volatiles & three-level low-nitrogen combustion technology of fuel, air and flue gas at the same time. Boiler’s initial NOx emission is less than 150mg/m³, initial CO emissions is less than 100mg/m³, eliminating no black smoke.
4. Unique empty load channel design ensures temperatures of flue gas entering the dense convective heating surface <650℃,with coking eliminated, initial emission concentration of smoke & dust ≤600mg/Nm³; 5. The dense heating surface and equal flue gas velocity design reduces local resistance, saves system power consumption, and prevents ash accumulation due to low flue gas velocity at the end. 6. Boiler has annual operating time more than 8,000 hours, with fast fire & pressure rise, sufficient output, and 10% overload operating capacity.

Description

Product Name: Vertical Corner Tube Biomass Steam Boiler
Product Model: DHW Series
HS Code: 84021900
Manufacturing Standards: ASME/EU/GB
Packing: Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.
Application Range: 10t/h≤D≤130t/h; P≤9.8MPa; T≤540 ℃

Parameters for 10t/h ~ 30t/h

Model Parameters DHW10 DHW15 DHW20 DHW25 DHW30
Structure Single-drum horizontal water tube boiler
Rated evaporation (T/H) 10 15 20 25 30
Working pressure (MPa) 1.25;1.6 1.25;1.6 1.25;1.6 1.25;1.6 1.25;1.6
Steam temperature (saturated °C) 194;204 194;204 194;204 194;204 194;204
Slightly superheated steam temperature (℃) 230-250 230-250 230-250 230-250 230-250
Feed water temperature (℃) 104 104 104 104 104
Boiler efficiency (%) ≥90 ≥90 ≥90 ≥90 ≥90
Design fuel Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw
Heating area (M²) 549.23 729.72 1035.62 1230.53 1470.24
Full water capacity (M³) 11.2 14.8 16.5 17.6 21.5
Exhaust gas temperature (℃) ≤90 ≤90 ≤90 ≤90 ≤90
Combustion mode Negative micro-pressure sliding combustion
Applicable altitude (m) Areas with altitude less than 500 meters
Dimensions of boiler proper (L×W×H) (mm) 6000×4310×8600 8170×3470×11500 8290×3760×12300 8320×3920×12500 10120×5730×17700
Dimensions after installation (L×W×H) (mm) 12000×6650×10640 11935×6500×15200 12140×6920×15700 12180×7150×15960 14180×7530×19700
Main steam valve diameter (mm) DN150 DN200 DN200 DN200 DN250
Safety valve diameter (mm) 2×DN80 2×DN100 2×DN100 2×DN125 2×DN150
Water inlet diameter (mm) DN50 DN65 DN65 DN80 DN80
Blow-down diameter (mm) 40;50 40;50 40;50 40;50 40;50
Ash Discharge System Chain-and-Flight Ash Remover
Ash disposal system Customized
Water treatment system Customized
Desulfurization and denitrification system Customized
Deaerator feed water pump Flow(m³/h) 10–12 15–18 20–24 25–30 30–36
Lift(m) 50–60 50–60 50–60 50–60 50–60
Boiler feed water pump Flow(m³/h) 10–12 15–18 20–24 25–30 30–36
Lift(m) 168–200 168–200 168–200 168–200 168–200
Control cabinet Customized
Primary Air Fan Flow(m³/h) 11800 17700 23600 29500 35400
Pressure (Pa) 3200 3264 3329 3396 3464
Secondary Air Fan (FGR) Flow(m³/h) 4175 6263 8350 10438 12525
Pressure (Pa) 3700 3774 3849 3926 4005
Tertiary Air Fan Flow(m³/h) 7000 10500 14000 17500 21000
Pressure (Pa) 3700 3774 3849 3926 4005
Induced draft fan Flow(m³/h) 16700 25050 33400 41750 50100
Pressure (Pa) 4000 4200 4410 4631 4862
Soot blower G-type fixed-rotary type/ Impulse type
Dia. & Height of stack(mm) According to the local environmental protection requirements / environment impact assessment report

Note:
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.
2. We can design and manufacture boilers with other parameters according to customers’ requirements.

Parameters for 40t/h ~ 75t/h

Model Parameters DHW40 DHW50 DHW60 DHW75
Structure Single-drum horizontal water tube boiler
Rated evaporation (T/H) 40 50 60 75
Working pressure (MPa) 1.25;1.6 1.25;1.6 1.25;1.6 1.25;1.6
Steam temperature (saturated °C) 194;204 194;204 194;204 194;204
Slightly superheated steam temperature (℃) 230-250 230-250 230-250 230-250
Feed water temperature (℃) 104 104 104 104
Boiler efficiency (%) ≥90 ≥90 ≥90 ≥90
Design fuel Bulk biomass materials such as forest wastes, sliced materials; bundled materials such as bean stalks, corn stalks and rice straw
Heating area (M²) 1709.9 2312.56 2712.21 3287.65
Full water capacity (M³) 23.3 28.5 29.8 33.6
Exhaust gas temperature (℃) ≤90 ≤90 ≤90 ≤90
Combustion mode Negative micro-pressure sliding combustion
Applicable altitude (m) Areas with altitude less than 500 meters
Dimensions of boiler proper (L×W×H) (mm) 11850×8000×21790 12350×8000×22280 13100×7800×24580 13920×8300×25920
Dimensions after installation (L×W×H) (mm) 16720×10500×23790 17220×10720×24280 26700×11800×26580 27950×12600×27950
Main steam valve diameter (mm) DN250 DN300 DN350 DN350
Safety valve diameter (mm) 2×DN150 2×DN200 2×DN250 2×DN250
Water inlet diameter (mm) DN80 2×DN80 2×DN100 2×DN125
Blow-down diameter (mm) 40;50 40;50 40;50 40;50
Ash Discharge System Chain-and-Flight Ash Remover
Ash disposal system Customized
Water treatment system Customized
Desulfurization & denitrification system Customized
Deaerator feed water pump Flow (m³/h) 40–48 50–62 60–72 60–72
Lift (m) 50–60 50–60 50–60 50–60
Boiler feed water pump Flow (m³/h) 40–48 50–62 60–72 60–72
Lift (m) 168–200 168–200 168–200 168–200
Control cabinet Customized
Primary Air Fan Flow (m³/h) 47200 59000 70800 94400
Pressure (Pa) 3533 3886 4275 4703
Secondary Air Fan (FGR) Flow (m³/h) 16700 20875 25050 33400
Pressure (Pa) 4085 4167 4583 5042
Tertiary Air Fan Flow (m³/h) 28000 35000 42000 56000
Pressure (Pa) 4085 4494 4943 5437
Induced draft fan Flow (m³/h) 66800 83500 100200 133600
Pressure (Pa) 5105 5360 5896 6486
Soot blower G-type fixed-rotary type/ Impulse type
Dia. & Height of stack (mm) According to the local environmental protection requirements / environment impact assessment report

Note:
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.
2. We can design and manufacture boilers with other parameters according to customers’ requirements.