首页 » Product » DHS Vertical (Modular) Corner Tube Gas Steam Boiler

DHS Vertical (Modular) Corner Tube Gas Steam Boiler

1. Boiler proper utilizes self-supporting vertical corner tube structure, with high strength & stability, safe and reliable without shaking or surging.
2. Steam boiler has a single drum. Drum is in external and unheated without numerous densely expansion (welding) pipe holes.
3. Steam boiler utilizes natural circulation + forced circulation (auxiliary). Vertical layout offers a greater height difference than traditional products, ensuring safer water circulation.
4. Large second-passage space provides ample heating surface arrangement in boiler proper, and the rear section is equipped with economizer and condenser (air preheater) for high efficiency.
5. Equal flue gas velocity design for dense convection heating surfaces makes flue gas velocity rationally controlled, prevents shaking of the heating surface.
6. Reserving sufficient space between densely heated surfaces for inspection & maintenance makes easy entry & exit of furnace & furnace chamber, making inspection & maintenance more convenient.
7. Modular design, high assembly degree, short installation period, small base space, more suitable for large capacity boilers.

Description

Product Name: Vertical (Modular) Corner Tube Gas Steam Boiler
Product Model: DHS Series
HS Code: 84021900
Manufacturing Standards: ASME/EU/GB
Packing: Boiler proper in nude packing, auxiliaries in steel frames for bulk vessel.
Application Range: 60t/h<D≤160t/h; P≤9.8MPa; T≤540 ℃

Parameters

Model / Parameters DHS40 (Modular) DHS50 (Modular) DHS65 (Modular) DHS75 (Modular) DHS100 (Modular) DHS130 (Modular)
Rated evaporation (T/H) 40 50 65 75 100 130
Rated working pressure (MPa) 1.25~9.8
Saturated steam temperature (℃) 194(1.25MPa) / 204(1.6MPa) / 226(2.5MPa) / 250(3.82MPa)
Superheated steam temperature (℃) ≤540
Rated feed water temperature (℃) 104(P≤3.82MPa) / 128(P≤5.4MPa) / 157(P≤9.8MPa)
Full water capacity (m³) 22.3 27.5 28.6 33.3 40.2 46.7
Design thermal efficiency (%) ≥99.2 ≥99.2 ≥99.2 ≥99.3 ≥99.5 ≥99.7
Exhaust gas temperature (℃) ≤65 ≤65 ≤65 ≤65 ≤65 ≤65
Design fuel Natural gas, city gas, gas, coke oven gas, 0# light diesel, etc.
Transport weight of the largest component (t) 30 37 42 45 53 65
Dimensions of boiler proper (L×W×H) (m) 8.6×4×12.4 11×4.1×13.2 11.2×4.2×15.9 11.6×4.2×16.5 14×4.3×20.5 10.6×8.3×15.5
Dimensions after installation (L×W×H) (m) 10.2×5.5×13.2 12.4×7.7×14 12.7×7.8×16.8 13×8×17.3 15.5×9.6×21.3 12.2×10.8×16.3
Interface
diameter (mm)
Main steam valve DN250 DN250 DN250 DN300 DN300 DN300
Safety valve 2×DN150 2×DN150 2×DN150 2×DN150 2×DN250 1×DN250 / 1×DN300
Water inlet valve DN100 DN100 DN125 DN125 DN150 DN150
Blowdown valve DN50 DN50 DN50 DN50 DN50 DN50

Note:
1. The right to interpret this product belongs to Brit Thermal Energy Equipment Co., LTD., the design data may subject to changes without prior notice, the final design drawing shall prevail.
2. We can design and manufacture boilers with other parameters according to customers’ requirements.